![Pacific energy ALDERLEA T5 LE Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/pacific-energy/alderlea-t5-le/alderlea-t5-le_installation-and-operating-instructions-manual_3137596022.webp)
22
ALT5 LE Insert 230819-32
100003038
Fan Speed Controller Relocation
The fan speed controller is factory installed under the ash lip on the right hand side. If required, it can be
relocated to the left side by following the instructions below. To make this as easy as possible, it is suggested
that this be done prior to fitting the surround and installation into the fireplace:
1. Remove the decorative top by tilting up slightly and lifting away from the unit (Figure 19).
2. Lift up on each fan shield and remove. Set aside to prevent damage (Figure 20).
Figure 19: Decorative cover removal.
Figure 20: Fan shield removal.
Figure 21: Disconnecting fan wires.
Figure 22: Unscrew thermal snap
switch.
3. Disconnect the wires from the fans, Left & Right Side (Figure 21).Unscrew thermal snap switch leaving
the wires connected (Figure 22). Take note of where the wires are routed and secured. They must be
positioned correctly to avoid damage.