Pacific Data Systems Feedlot Weather Station Скачать руководство пользователя страница 9

 
 
 
 

 

Routine Maintenance 

 
The  system  should  be  checked  at  least  once  a  year  depending  on  conditions.  Systems  located  in 
corrosive or coastal environments should be checked more frequently. 
Check that all the mountings are secure and free from damage and corrosion. Replace parts where 
required. 
Check that the tripod is still vertically aligned and there is no damage to it and the bolts are tight. 
Check  the  sensors  and  solar  panels  are  orientated  correctly,  cables,  connectors,  sensors  and  solar 
panels are clean and undamaged. 
Dismantle the tipping bucket clean and test. 
Replace  humidity  sensor  in  the  Weather  Sensor.    Available  from  PDSA.  Part  No.  PDS-WX-RH-
MODULE 
Check the logger and connectors is clean and free from damage and there has been no sign of water 
or insect damage. 
Ensure any vents are clean. 
Check condition of the battery and replace if weak. Part No. FED-RM12-12DC 
Check the connection to the SatVUE Weather Portal and all the parameters are being logged. 
 
 
If you require further assistance, please contact (+617) 3361 2000 or [email protected] 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
All brand and product names are trademarks or registered trademarks of their respective owners. 
 

Note

 Information found within this manual is subject to change without notice. Screen images and 

hardware shown may vary slightly from actual product. 
 

©2020 Pacific Data Systems Australia Pty Ltd. All rights reserved. 

 

Содержание Feedlot Weather Station

Страница 1: ...Assembly Instructions Feedlot Weather Station Version 1 0 February 2020...

Страница 2: ...rd spikes 1 Antenna 1 Spare fuse kit inside logger 10 Cable ties You will need general tools including the following PPE Set of metric spanners Adjustable spanner Set of screwdrivers Large Hammer to d...

Страница 3: ...he star Picket using the supplied bolts Use a spirit level to make sure the tripod is vertical To help against gnawing lubricate the threads on the stainless steel bolts before assembly Fig 1 Assemble...

Страница 4: ...weather sensor and attach the plug taking care to note its orientation Secure it with the white lock ring on the tripod adaptor Screw the tripod adaptor and sensor on to the top of the tripod orienta...

Страница 5: ...ase to the enclosure Screw the antenna to the antenna base and hand tighten firmly making sure the O ring is in place Fig 5 Fig 5 Tipping Bucket Rain Gauge Fit the supplied bird spikes to the tipping...

Страница 6: ...able ties Fig 8 Secure the Weather sensor cable to the tripod If you have problems with birds attacking the cables they can be protected with conduit or equivalent The connectors will pass through 32m...

Страница 7: ...is flush when it is on Refer to the SatVUE Login Details document supplied in the Customer Documentation Folder that was shipped with your weather station Using this document login to the SatVUE porta...

Страница 8: ...ich allows you view the latest data from the station as well as trends over time More documentation on the SatVUE portal can be found here https www satvue com au documentation When the weather statio...

Страница 9: ...sensor in the Weather Sensor Available from PDSA Part No PDS WX RH MODULE Check the logger and connectors is clean and free from damage and there has been no sign of water or insect damage Ensure any...

Отзывы: