background image

 

1. 

INPUT POWER

 12VAC 40VA SUPPLIED (voltage measurement must be  (12.5-14.0 VAC)  

OR 12VDC 2A adjustable power supply (voltage measurement must be 13.5-14.0 VDC)  
 

2. 

12 VDC 4Ahr BATTERY BACK-UP (OPTIONAL) 

WARNING: THIS IS NOT INPUT POWER

 

 

3. 

DOOR 2 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE  
 

4. 

DOOR 1 DRY CONTACT RELAY, MUST USE SEPARATE POWER FOR DOOR STRIKE  
 

5. 

TELEPHONE OUT LOOP TO NEXT QC SYSTEM, IF TELEPHONE LINE IS SHARED 
 

6. 

 

TELEPHONE INPUT ANALOG DIAL TONE “ONLY”  

 

7. 

AUX 1 AND AUX 2 FOR EXIT SWITCH, LOOP DETECTOR OR ANY INPUT DEVICE WITH DRY CONTACT OUTPUT.  
 

8. 

DOORS1 AND DOORS 2 SENSOR. 

WARNING: THESE ARE NOT DOOR CONTACTS

 

 

9. 

RS-485 PORT, CONNECT TO SLAVE UNITS (USCR, UCRM, USKP AND USKPR) UP TO 8 UNITS  
 

10.  26-WIEGAND INPUT. PROPRIETARY CARD READER IS BUILT-IN ON THE QC SERIES. DISCONNECT THE BUILT-IN READER IF YOU 

ARE USING YOUR OWN CARD READER.  
 

11. 

FACTORY USE “ONLY” TO POWER THE QWCM IP MODULE AND FAN. 

WARNING: 

“DO NOT USE THE +12VDC POWER TO POWER 

ANY OTHER DEVICES”. 

 

12.  AATA2 INPUT POWER 5VDC 3.0A (SUPPLIED) 

 

13.  AATA2 INTERNET CONNECT TO ROUTER OR SWITCH 

 

14.  AATA2 LAN CONNECT TO QWCM NO.17 

 

15.  AATA2 PHONE ANALOG DIAL TONE CONNECT TO NO. 6 

 

16.  QWCM POWER AND COMMUNICATION CONNECT TO (#11 12VDC POWER) AND (#18 RS-232). DO NOT UPLUG THIS CONNECTOR 

WITH POWER ON FACTORY PREWIRED 
 

17.  QWCM ETHERNET PORT CONECT TO ROUTER OR SWITCH. 

DO NOT CONNECT TO AATA2 NO. 14 

 

18.  RS-232 CONNECT TO (#16 ON QWCM) FACTORY PREWIRED 

Technical Support is available  
Monday-Friday 7:00 am-4:00 pm PST at 1-888-678-
7224 
Technical Info and complete manual are available online 
www.pach-co.com

 

 

 