Relay output is Form C Dry Contact, 125VAC/25A, 28VDC/10A or 250VAC/7A. Two conductors 16-18 gauge solid wires are
recommended. See the door strike manufacturer wiring requirements.
Figure 3
is
Normally Opened DC Door Strike
(polarity sensitive). Normally Opened Door Strike means the door is
locked if the door strike is not energized/powered and the door is unlocked if the door is energized/powered.
If AC door strike is used, polarity is not necessary.
Figure 4 is
Normally Closed DC Door Strike
(polarity sensitive). Normally Closed Door Strike means the door is
locked if the door strike is energized/powered and the door is unlocked if the door is not energized/powered.
If AC door strike is used, polarity is not necessary.
POWER
12VAC/40VA(supplied) or 12DC/40VA, see figure 1 for wiring diagram.
• Two conductors 16-18 gauge solid or stranded wires are required. Do not use the system’s transformer to power other
equipment.
• Measuring the input voltage, it must be read between 12.5-14 VAC if AC transformer is used under load (system is on) or
13.5-14.5 VDC under load (system is on) if DC power supply is used.
If 12 VDC/40VA power supply is used with battery back-up, see figure 5 for wiring diagram.
TURN THE POWER SWITCH (S1) TO ON (UP POSITION) AFTER THE POWER WIRES ARE CONNECTED.
SYSTEM’S OPERATIONS
System’s ID Number and Jumper Setting
• A maximum 32 of SCR9 can be interfaced with the AeGIS 9000 Series. Each of the SCR9 must have a unique ID number
(0-31). The ID number is selected using the S2 (rotary switch) and JP2, see table below.
5
Rotary Switch Setting with JP2 is ON
HEX
DECIMAL
HEX
DECIMAL
0
0
8
8
1
1
9
9
2
2
A
10
3
3
B
11
4
4
C
12
5
5
D
13
6
6
E
14
7
7
F
15
Rotary Switch Setting with JP2 is OFF
HEX
DECIMAL
HEX
DECIMAL
0
16
8
24
1
17
9
25
2
18
A
26
3
19
B
27
4
20
C
28
5
21
D
29
6
22
E
30
7
23
F
31