background image

Relay output is Form C Dry Contact, 125VAC/25A, 28VDC/10A or 250VAC/7A. Two conductors 16-18 gauge solid wires are 

recommended. See the door strike manufacturer wiring requirements.

Figure 3

is 

Normally Opened DC Door Strike

(polarity sensitive). Normally Opened Door Strike means the door is 

locked if the door strike is not energized/powered and the door is unlocked if the door is energized/powered.
If AC door strike is used, polarity is not necessary.

Figure 4 is 

Normally Closed DC Door Strike

(polarity sensitive). Normally Closed Door Strike means the door is 

locked if the door strike is energized/powered and the door is unlocked if the door is not energized/powered.
If AC door strike is used, polarity is not necessary.

POWER

12VAC/40VA(supplied) or 12DC/40VA, see figure 1 for wiring diagram. 

• Two conductors 16-18 gauge solid or stranded wires are required. Do not use the system’s transformer to power other 

equipment. 

• Measuring the input voltage, it must be read between 12.5-14 VAC if AC transformer is used under load (system is on) or 

13.5-14.5 VDC under load (system is on) if DC power supply is used.

If 12 VDC/40VA power supply is used with battery back-up, see figure 5 for wiring diagram.

TURN THE POWER SWITCH (S1) TO ON (UP POSITION) AFTER THE POWER WIRES ARE CONNECTED.

SYSTEM’S OPERATIONS

System’s ID Number and Jumper Setting

• A maximum 32 of SCR9 can be interfaced with the AeGIS 9000 Series. Each of the SCR9 must have a unique ID number 

(0-31). The ID number is selected using the S2 (rotary switch) and JP2, see table below.

5

Rotary Switch Setting with JP2 is ON

HEX

DECIMAL

HEX

DECIMAL

0

0

8

8

1

1

9

9

2

2

A

10

3

3

B

11

4

4

C

12

5

5

D

13

6

6

E

14

7

7

F

15

Rotary Switch Setting with JP2 is OFF

HEX

DECIMAL

HEX

DECIMAL

0

16

8

24

1

17

9

25

2

18

A

26

3

19

B

27

4

20

C

28

5

21

D

29

6

22

E

30

7

23

F

31

Отзывы: