AeGIS 8000 Series  

Quick Installation Guide & Software Operation 

Page 9 

12/21/01 

§ 

Check the red and orange wires, make sure 
they are soldered into the speaker. 

§ 

Turn the system’s power “OFF” and disconnect 
the speaker connector from the board. The 

speaker impedance must be 24 ohms. 

The visitor can’t hear the tenant from the 

system but the tenant can hear the visitor. 

§ 

Check the speaker and microphone connection 

on terminal marked CN4 on the board.  

§ 

Check the red and orange wires, make sure 

they are soldered into the speaker 

§ 

Press the “#” key as soon as you hear a dial 
tone, tap your finger into the microphone and 

you should hear the feedback from the speaker. 

The tenant can’t hear the visitor talking but 

the visitor can hear the tenant. 

§ 

Check the speaker and microphone connection 

on terminal marked CN4 on the board.  

§ 

Check the brown and black wires, make sure 

they are soldered into the microphone. 

§ 

Turn the system’s power “OFF” and disconnect 

the speaker connector from the board. The 
speaker impedance must be 24 ohms. 

DISPLAY PROBLEMS 

The Liquid Crystal Display (LCD) shows 
question marks (????). 
 

 
 

 
 

 
 

§ 

Turn the unit power “OFF” and “ON” 

§ 

Erase the memory chip (EEPROM) using 
Function Code 50. If you have trouble going to 

the programming mode, press the square red 
button and press “#” (you may still see the 

questions marks on the display, ignore it) and 
enter Function code 50 follow by “#” and press 

1 and ”#”. 

Function Code 50 will erase the 

whole database.

 

The Liquid Crystal Display (LCD) is blank, no 
display at all. 

§ 

The power LED must be “ON” (LED2 marked on 
the board). 

§ 

The Power Switch’s toggle must be on the left 
position (“ON”). 

§ 

Check the fuse (3 Amp 250 Volt) 

§ 

Measure the voltage on AC1 and AC2 (set your 

voltmeter to AC and put the probes on AC1 and 
AC2), it should read within 12VAC-13.8VAC. 

§ 

The LCD’s ribbon cable has red dots along the 
side. The red dots must be facing up. It must 
be connected to the terminal marked CN5 on 

the board. 

§ 

The LCD’s ribbon cable sits tight on the pins 

terminal marked CN5 on the board. 

§ 

The LCD’s ribbon cable is connected into the 

LCD’s terminal pin connector and the red dots 
along the side of the ribbon should be on the 

left side. 

§ 

Adjust the LCD’s intensity, see figure 2. 

§ 

Turn the system’s power “OFF”, wait for 15 
seconds and turn it “ON”. 

§ 

If the sunlight hits directly into the system’s the 
LCD, block the sunlight. If the LCD is readable 

after you block the sunlight, you may have to 
install the system onto different location or you 

can purchase the 7SHLD (sun sunshield). 

Note

the sunshield may not solve your problem if the 

sunlight hits horizontally into the LCD display. 
Direct sunlight may collect heat into the system 
and it may damage the system if the inside 

Содержание AeGIS 8000 Series

Страница 1: ...echnical Specification 2 Installation 3 Wiring Requirements 3 Power 3 Grounding 5 Telephone Line 5 Programming 5 System Operations 7 Trouble Shooting Guide 8 AeGIS 8000 Series Management Software 12 System Requirements 12 Software Installation 12 Modem Setting 12 Modem Connection 13 Creating Tenant Database 13 Upload 13 Download 13 Event Recording 14 ...

Страница 2: ...e serial number on the cabinet The system s failure is not caused by vandalism improper installation misuse or abuse Physically damaged product is not acceptable for repair or exchange within or after warranty The warranty will be void and null if the product has been repaired or modified by unauthorized party without authorization of Pach and Company Technical Department If for some reason your s...

Страница 3: ...s very essential You MUST follow the installation procedures block diagrams and installation requirements as specified in this section Wiring Requirements Two conductors stranded 18 gauge minimum shielded wire for all connections Surge protection MUST be installed to include lightning strikes on your two years warranty You must have an active telephone line You may share the line with your telepho...

Страница 4: ...AeGIS 8000 Series Quick Installation Guide Software Operation Page 4 12 21 01 Figure 2 ...

Страница 5: ...s If a PBX line is used connect the RJ 15 to the PBX s Analog Port Do not connect to a PBX s Digital Port The AeGIS 8000 Series works behind a PBX to dial either the extensions or outside lines it cannot dial both means if a PBX setting is enabled the system cannot dial the extensions behind a PBX P P P r r r o o o g g g r r r a a a m m m m m m i i i n n n g g g You can program the AeGIS 8000 Seri...

Страница 6: ... for keypad correlation 21 Open Door 2 Number The tenant can open the door remotely by pressing 8 default setting from a touch tone or pulse phone The number can be changed via programming as follow Select 0 9 if the system is in touch tone Select 6 9 if the system is in pulse Do not select the same number as door 1 02 Modify a Tenant Existing Tenant only See figure 3 for keypad correlation 40 Mas...

Страница 7: ...ant name you are intending to call is visible on the display press to initiate the call 2 Press and wait for dial tone and press the directory code If Multi systems are installed the others will display TEL LINE BUSY if one is used How to answer the AeGIS calls Answer the AeGIS calls and press the associate number to open the door remotely or hang up if you do not want to open the door The number ...

Страница 8: ...lash or comes ON press the keypad number 0 9 and the LED should be flashed every time the key number is pressed If it does not flash increase the sensitivity by turning the pot counter clockwise How to check the number of tenants on the system Press and hold 0 and press and release both keys The Welcome Screen will stop scrolling and then enter your valid 4 digits Master Code Press and the display...

Страница 9: ...e square red button and press you may still see the questions marks on the display ignore it and enter Function code 50 follow by and press 1 and Function Code 50 will erase the whole database The Liquid Crystal Display LCD is blank no display at all The power LED must be ON LED2 marked on the board The Power Switch s toggle must be on the left position ON Check the fuse 3 Amp 250 Volt Measure the...

Страница 10: ...e line and try to place a call Check the phone number on the system programming Check the phone line and make sure the telephone terminal box is grounded The visitor hears a radio station on the AeGIS system while talking to a tenant Check to see if the problem occurs on all tenants Disconnect the phone line from the AeGIS system and connect a standard phone into the phone line and try to place a ...

Страница 11: ...s 9 and you should get the following results Your meter should read to about 0 value if RC1 and NO1 contacts are used otherwise the system s relay is bad Your meter should read as an open circuit if RC1 and NC1contacts are used otherwise the system s relay is bad If use relay 1 make sure the gate strike is connected to relay 1 if you use relay 2 make sure the gate strike is connected to relay 2 se...

Страница 12: ...Modem 1200 BPS or Faster Software Installation Step 1 Insert the Pach Company CD ROM Step 2 Open My Computer Step 3 Open the CD ROM file and double click on Setup Follow the instruction to continue the installation Modem Setting Step 1 You must enable the function codes below locally Enable Auto answer function code 74 must be set to 1 on your AeGIS 8000 Enable Modem Programming function code 71 m...

Страница 13: ...o 11 digits Step 4 Enter the 4 digit access code number You may leave this field blank if access code is not needed Step 5 Enter Door 1 for relay 1 door 2 for relay 2 and door 3 for both relay 1 and 2 Step 6 Click on enter and the tenant data will show on the box as shown on figure 5 Step 7 Click on Save as if this is the first time you save the database or Save if you have already saved the datab...

Страница 14: ...ing Follow the table below to translate your Event Recording report The most current Event Recording will show first on the report Events Report DATE TIME SOURCE CODE ACTION CAUSE DESCRIPTION 03 31 1999 15 21 System Keypad 6666 Denied Bad Code Access code denied 03 31 1999 15 20 System Keypad 8888 Denied Bad Code Access code denied 03 31 1999 15 16 System Keypad 5555 Denied Bad Code Access code de...

Отзывы: