background image

Pach and Company

Chapter 3

Page 14

AeGIS 8000 Series

PROGRAMMING

FUNCTION CODE

PROGRAMMING

Step 4

Proceed to step 2 and select the same function code  or different 
function code to continue programming or press 

*

to exit the 

programming mode and you will hear “ 

three short beeps

”.

16

VERIFY THE CURRENT DATE

Step 1

Log on to programming mode, see instruction above.  The display 
will show

Step 2

Enter function code 16 then press #, the display will show the 
current date for about 3 seconds

Step 3

Proceed to step 2 and select the same function code  or different 
function code to continue programming or press 

*

to exit the 

programming mode and you will hear “ 

three short beeps

”.

17

SET SYSTEM’S DATE

Step 1

Log on to programming mode, see instruction above.  The display 
will show

Step 2

Enter function code 17 then press #, the display will show 

then it will show

Step 3

Enter the current date then press #

MM

= Current month

DD

= Current date

YYYY

= Current Year

D

= Current day (1=Mon, 2=Tue, 3=Wed, 4=Thu, 5=Fri, 6=Sat

7=Sun).

Step 4

Proceed to step 2 and select the same function code  or different 
function code to continue programming or press 

*

to exit the 

programming mode and you will hear “ 

three short beeps

”.

19

INITIALIZE EVENT RECORDING

The event buffer will hold up to 600 events. 
Download the events via software and and save
them into your hard-drive. Then clear the even
buffer. It will save your time to download the
next events.

Step 1

Log on to programming mode, see instruction above.  The display 
will show

Step 2

Enter function code 19 then press #, the display will show 

Step 3

Enter

• 1 = clear the events buffer
• 0 = cancel deletion then press #.

Step 4

Proceed to step 2 and select the same function code  or different 
function code to continue programming or press 

*

to exit the 

programming mode and you will hear “ 

three short beeps

”.

Select Func:

_ _

FRI JAN. 17, 2003

Select Func:

_ _

Enter

date

Date: MMDDYYYYD

Select Func:

_ _

InitEVR (0,1):

_

Содержание AeGIS 8000 Series

Страница 1: ...AeGIS 8000 Series Installation and Programming Manual PACH COMPANY 941 Calle Negocio Phone 1 888 678 7224 www pach co com San Clemente CA 92673 Fax 949 498 6879 REV 7 0...

Страница 2: ......

Страница 3: ...r 2 time interval 13 14 Set system s time 13 15 Daylight Saving time 13 16 Verify the current time 14 17 Set system s date 14 19 Initialize event recording 14 20 Relay 1 door 1 remote access number se...

Страница 4: ...ormation herein implied Pach and Company does not assume any liability for any damages which may arise in installation or use of the AeGIS 8000 Series Pach and Company does not assume liability for an...

Страница 5: ...entered on the system keypad The system parameters and tenants data will be entered via the keypad and the LCD provides easy display EEPROM technology is used on AeGIS 8000 series The tenant database...

Страница 6: ...Series Some of the parts may not be listed below If you have missing items please contact your distributor or Pach and Company at 888 678 7224 AeGIS 8000 System XMFR Power Transformer 12VAC 40VA 3 pin...

Страница 7: ...to vandalism or malicious mischief improper installation abnormal physical or electrical stress lightning power surges misuse negligence accidents or Natural disasters 3 Warranty is immediately null...

Страница 8: ...all warranty issues 8 Distributor and or Dealer Installer are responsible for all shipping charges incl freight and insurance fees for products shipped to Pach and Company repair center 9 Pach and Co...

Страница 9: ...extends only to wholesale customers who buy direct from Pach and Company or through Pach and Company s normal distribution channels Consumers must obtain warranty information from the selling dealer...

Страница 10: ...er including but not limited to any expenses to install uninstall or reinstall hardware software firmware related to warranty issues product enhancements or product failures IMPORTANT REPAIR NOTE Pach...

Страница 11: ...system is very essential You MUST follow the installation procedures block diagrams and installation requirements as specified in this chapter Figure 2 1 Pach and Company Chapter 2 Page 4 AeGIS 8000...

Страница 12: ...Note The system can only be programmed to dial another extension or the outside line it cannot dial both If the system is programmed to dial the outside line then the system cannot be used to dial ano...

Страница 13: ...uring the power failure The AeGIS 8000 Series have built in charging circuit for battery backup Recommended battery is ABAT1 12 VDC 4 5 Ahr rechargeable The life of the battery is approximately 8 10 h...

Страница 14: ...the manufacturer to obtain a replacement key with nominal charge Step 2 Locate a square RED or GREEN button on the board and press and release it the display will show xxxx is the 4 digit master code...

Страница 15: ...ntry code is used to enter the building via a system keypad If you decided to use the same 4 digit code for all tenants you only need to program the access code into one directory Step 1 Log on to pro...

Страница 16: ...ectory code must be available to edit an existing tenant directory If the directory code is not available see function code 78 to retrieve it or use software to edit it NOTE Function code 78 cannot re...

Страница 17: ...4 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear three short beeps 04 CLEAR ALL TENANT D...

Страница 18: ...8 hours to unlock door 1 99 hours to unlock door 1 for indefinite time 00 hours to lock door 1 then press or to cancel Step 4 Proceed to step 2 and select the same function code or different function...

Страница 19: ...DEFAULT SETTING IS Welcome to Pach s Telephone Access System The welcome message consists of three segments Each segment is 16 characters long Step 1 Log on to programming mode see instruction above T...

Страница 20: ...n code or different function code to continue programming or press to exit the programming mode and you will hear three short beeps 14 SET SYSTEM S TIME Step 1 Log on to programming mode see instructi...

Страница 21: ...3 Enter the current date then press MM Current month DD Current date YYYY Current Year D Current day 1 Mon 2 Tue 3 Wed 4 Thu 5 Fri 6 Sat 7 Sun Step 4 Proceed to step 2 and select the same function co...

Страница 22: ...g on relay 2 to a different number do not select number 9 if you do so the second relay cannot be released using the 9 Step 1 Log on to programming mode see instruction above The display will show Ste...

Страница 23: ...eed to step 2 and select the same function code or different function code to continue programming or press to exit the programming mode and you will hear three short beeps 70 SELECT COMMUNICATION PRO...

Страница 24: ...ss to exit the programming mode and you will hear three short beeps 73 TONE OR PULSE DIALING Default setting is 1 for tone Step 1 Log on to programming mode see instruction above The display will show...

Страница 25: ...ed 0 Speaker beep is OFF when door is unlocked then press Step 4 Proceed to step 2 and select the same function code or different function code to continue programming or press to exit the programming...

Страница 26: ...ee short beeps 79 TALK TIME Default setting is 060 seconds The length of time the visitor can talk to the tenant The talk time timer starts as soon as the system initiates the call The talk time can b...

Страница 27: ...to answer your call Step 4 Tenant must press the correspondent key to release the door By default press 9 to release door 1 relay 1 or 8 to release door 2 relay 2 TO CALL THE SYSTEM The tenant can cal...

Страница 28: ...ruction above The display will show Step 2 Press 91 then press the system will show the total number of tenant Note A tenant directory with no name will not be included as a total number of tenant TO...

Страница 29: ...fore measuring the impedance No dial tone when is pressed Make sure the speaker s blue connectors is connected Make sure the LCD shows a welcome message Check the speaker impedance 19 24 ohm Check the...

Страница 30: ...the display shows door open check the system s relay using an ohm meter The meter should read a closed circuit across the RC1 and NO1 or RC2 and NO2 or open circuit across the RC1 and NC1 or RC2 and N...

Страница 31: ...devices you can connect to your telephone line your telephone company will provide you upon request In the unlikely event your AeGIS system develops a problem IMMEDIATELY DISCONNECT IT FROM YOUR TELE...

Страница 32: ...for space or move cursor to the right Press 8 then 0 for backspace or move cursor to the left Press to clear or reset the lettering sequence Sometimes the letter key strokes are out of sequence press...

Отзывы: