2.
Insert line cord into the rear panel Power Cord Input and plug into a properly grounded
(earthed) receptacle. Verify that the power supply is properly rated to the power
requirement of your PH 100 system.
3.
Set up the adjustable Magnetic Board Holder according to preferred height (using rails and
magnetic feet) and place the PCB onto the holder:
4.
Turn on power by using the Main Power Switch on the back panel of the PH 100.
5.
Set the Preheater to the desired temperature
by tapping the “+” (plus) “Increase
Temperature” or “-“ (minus) “Decrease Temperature” buttons.
6.
Wait for temperature to stabilize and start soldering/repair/rework operations using a
soldering iron or other rework tools.
Main Menu Screen
1.
Set Temperature: Set the temperature by tapping the number. A numeric keyboard will
appear that will allow you to set the temperature from 20 - 200°C (68 - 392°F). Temperature
can also be set by tapping the
“+” (plus) “Increase Temperature” or “-“ (minus) “Decrease
Temperature” buttons.
2.
Actual Temperature: Shows actual temperature of the internal heater if the device is set to
Internal Sensor Control. If the temperature is being controlled by one of the two external
thermocouples (Top Sensor or Bottom Sensor), no value is shown here. (Offset Values are
only available when PH 100 is set to Internal Sensor Control).
3.
Temperature Curve: The thinner line indicates the Set Temperature. The bold line shows
the Actual Temperature Curve.
4.
Increase (+) Temperature Button: Tap button to increase set temperature (hold for quick-
set).
5.
Decrease (-) Temperature Button: Tap button to decrease set temperature (hold for quick-
set).
6.
Icon Bar: Displays key operational information icons during use. See
Full Operations
Manual
for icon explanations.
7.
Heater Settings Menu Button: Tap this button to open the Heater Settings Menu screen.
See
Full Operations Manual
for Heater Settings Menu explanations.
8.
Device Settings Menu Button: Tap this button to open main Device Settings Menu screen.
See
Full Operations Manual
for Device Settings Menu explanations.
9.
Power Meter Button: Tap the button to set the power level of the preheater. Options are
1600W or 800W. The meter shows the duty cycle or power level at which the heater is
currently operating.
10. Password/Screen Lock Button: Tap this button to lock the screen. On the Icon Bar a lock
appears. Tap the button again and enter password to unlock.
11. Top Sensor: Shows the Top Sensor temperature when a thermocouple is in use. When not
in use, will display “N.C.” (Not Connected).
12. Bottom Sensor
:
Shows the Bottom Sensor temperature when a thermocouple is in use.
When not in use, will display “N.C.” (Not Connected).
DOWNLOAD THE FULL OPERATIONS MANUAL AVAILABLE ONLINE AT: