17
QUICK START - BASIC OPERATION
QUICK START PROCEDURE
The MBT 201A and 101A systems are very easy to operate. As received from the factory, the system can be
quickly set up for use in standard soldering/desoldering operations. Simply perform the following Quick Start
Procedure to begin system operation.
1. Insure that the Set-Up procedure has been performed; check for the following:
a) VisiFilter connection to the AUTO SNAP-VAC Port on the front panel of the power source.
b) Handpiece cable and air hose connections to the power source.
NOTE
If more than one air-operated handpiece (SX-70, TJ-70 or TP-65) is
connected to the power source, insure that only one of the Air Hoses is
connected to either the VisiFilter assembly (connected to the AUTO
SNAP-VAC Port) or the Controllable PRESSURE Port. Attachment to
both simultaneously will cause a deterioration in performance.
a) All handpiece Tip & Tool Stands set up as desired (using instructions enclosed).
b) Proper tips installed in handpieces.
c) Power cord connection between the house AC supply receptacle
and the power source.
2. Turn the Power Switch to the "On" ("l") position.
3. Adjust the Variable Temperature Control of each channel with a
connected handpiece to the desired tip temperature.
4. Observe the Channel LEDs as the Set Tip stabilizes at the desired Tip
Temperature, the associated LED will flash at a constant rate.
NOTE
Read the "Operation" section of this manual to utilize the full capabilities
of the system. This is especially important when using large soldering tips.
Refer to the enclosed handpiece manuals for a complete description of
handpiece capabilities.
Figure 9. Power Up
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com