©2012 PACE Inc., Vass, North Carolina, All Rights Reserved                                                                                                         
 

Page 4

  

 

Operation 

 

1.  Remove Arm-Evac 105 from packaging and place in suitable position. 
 
2.  Plug the supplied power cord into receptacle at left side of unit, ensuring that it is connected to a 

properly grounded outlet. 

 
3.  Fit appropriate fume collection accessories. 
 
4.  Turn on the Arm-Evac 105. 

 

Maintenance 

 

Fuses: 

The fuse is located in a sliding tray at the left side of the unit, just below the power receptacle.  
Each Arm-Evac is supplied with one replacement fuse, also located in the sliding tray. 

 
 
Fan Assy: 

The Arm-Evac 105 is fitted with a brush-less, single inlet fan assembly, which does not require 
routine maintenance.  It is important that fume extractor filters are changed on a regular basis to 
protect the fan assembly. 

 

 

 

A vent is located on the right side of the unit to allow the cleaned air to return to the workplace.  
Do not cover this vent as this may cause damage to the fan assembly. 
 
Never operate the Arm-Evac 105 without filters installed. 

 

 

 

Troubleshooting 

 

Symptom 

Possible Causes 

Solution 

System will not turn on. 

No power supplied to unit 

Make sure the power cord is fully seated and 
that the power is turned on. 

Reduced Airflow 

Filter blocked. 

 Check & change filter(s) 

Arm attachment not installed correctly. 

Make sure all accessories are fully seated. 

 
If the unit does not work after checking the above, please contact PACE, or your Authorized PACE Distributor if 
outside U.S. 

 

Содержание ARM-EVAC 105

Страница 1: ...ARM EVAC 105 Central Filter Unit MANUAL NO 8881 0990 REV C...

Страница 2: ...ENTS Safety 1 Introduction 2 Specifications 2 Features 3 Set up 3 Operation 4 Maintenance 4 Troubleshooting 4 Filter Replacement Spare Parts 5 Warranty 7 WARNING Read the safety setup information sect...

Страница 3: ...recommended To insure continued effective performance the following guidelines must be followed Dangers 1 PACE Fume Extractors are not intended to be used as a substitute for devices such as personal...

Страница 4: ...sanding bench top machining grinding 5 An Extended Life Filter and High Capacity Pre Filter for longer maintenance intervals during normal soldering operations The Arm Evac 105 Fume Extractor uses sp...

Страница 5: ...or that airflow from the exhaust port is not restricted in any way Proximity to work area The unit should be placed as close to the work area as possible Do not create any sharp bends in the flexible...

Страница 6: ...an assembly which does not require routine maintenance It is important that fume extractor filters are changed on a regular basis to protect the fan assembly A vent is located on the right side of the...

Страница 7: ...ver depending on your particular process the filter may need to be changed more or less frequently A visual inspection on a weekly basis is recommended Replacing the Pre Filter 1 Remove the Filter acc...

Страница 8: ...ed paper filter activated carbon media Benchtop Adhesives Procedures Gluing Applications Circuit Board Cleaning Laboratory Applications 8883 0921 P1 Cleanroom Filter Comprised of HEPA pleated paper fi...

Страница 9: ...le for all costs of shipping equipment to PACE or other warranty location for warranty service EXCEPT FOR THE REMEDY ABOVE DESCRIBED UNLESS OTHERWISE REQUIRED BY APPLICABLE LAW PACE WILL HAVE NO OTHER...

Отзывы: