©2018 PACE Inc., Vass, North Carolina, All Rights Reserved Page 4
System Power
1. Insert the female end of the power cord into the AC Power Receptacle on the rear panel of the power
source.
2. Plug the prong end (male end) of the power cord into an appropriate 3 wire grounded AC supply
receptacle.
Setup and Operation
Operation
1. Ensure the Set-Up procedure has been performed. Check
the following:
•
Handpiece connection to the power source.
•
Proper Tip-Heater Cartridge is installed in
handpiece.
•
Power cord is connected to both an appropriate AC supply and the ADS200 unit.
2. Turn the Power Switch On ("I").
3. Press the Scroll Up ( ) Key. After a brief start-up sequence, the Set Temperature will be displayed.
4. Adjust the temperature by pressing and holding Scroll Up ( ) Key or Scroll Down (
) key. Observe the
display as the Set Temperature increases first in increments of 5° and then in increments of 10°. When
the desired temperature is reached, release the key.
5. NOTE: The Set Temperature can only be adjusted within the defined temperature limits which will be
260°- 460°C (500°-800°F) as set at the factory. If the upper limit has been reached, the display will read
“HiL”; if the Lo limit is reached, the display will read “OFF”. Temperature limits can be adjusted in the
Set-Up menu.
Digital Control LED Indicator Light
The colored LED on the power source front panel indicates when the handpiece is heating, has reached the set
temperature, or if a fault has occurred. In the factory default Temperature Match Mode of “OC0” the following
LED conditions are observed;
LED Full On Red
– A fault has occurred such as nothing is plugged into the Power Receptacle on the front of
the unit or the Tip-Heater Cartridge is not fully inserted into the handle. Check the Tip-Heater Cartridge
installation and the handpiece connection to the front panel.
LED Full On Green
– The Tip-Heater Cartridge has reached the Set Temperature.
LED Full On Amber
– The Tip-Heater Cartridge in the connected handpiece is currently heating up to the Set
Temperature.
LED Off
- Unit is not turned on or is in Temperature SetBack.
For description of LED behavior in other Temperature Match Modes, refer to the Temperature Match Feature
manual on our website at https://paceworldwide.com/ads200-temperature-match-mode-manual.