PEC 013
Page
50
of
71
12/20/13
Parameter Name
Number
Min/Max/Default/Units
Rate to increase PTO speed with Remote
Set/Accel switch held
N093
MIN = 10 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 250
(RPM/SEC)
Rate to decrease PTO speed with Remote
Resume/Decel switch held
N091
MIN = 10 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 200
(RPM/SEC)
Maximum Torque Limit in PTO
N077
MIN = 148 (lb-ft)
MAX = 1902 (lb-ft)
DEFAULT = 1902 (lb-ft)
ON/OFF Requirements
PTO Mode
Note: Interlocks must be programmed to 1 (ON) to affect the ON/OFF requirements
ON (Any)
OFF (Any)
PTO ON/OFF switch in the ON position
PTO ON/OFF switch in the OFF position
Clutch pedal NOT depressed (if PTO
OFF Interlock Clutch Pedal Operated is
programmed to 1)
Clutch pedal depressed (if PTO OFF
Interlock Clutch Pedal Operated is
programmed to 1)
Service brake NOT depressed (if PTO
OFF Interlock Service Brake Pedal
Operated is programmed to 1)
Service brake depressed (if PTO OFF
Interlock Service Brake Pedal Operated is
programmed to 1)
Park Brake Set (if PTO ON/OFF Interlock
Park Brake Set is programmed to 1)
Park Brake NOT Set (if PTO ON/OFF
Interlock Park Brake Set is programmed to
1)
Vehicle speed
≤ PTO ON Interlock
Vehicle Speed Limit (if PTO ON Interlock
Vehicle Speed Limit is programmed to
≥
1)
Vehicle speed > PTO ON Interlock Vehicle
Speed Limit (if PTO ON Interlock Vehicle
S
peed Limit is programmed to ≥ 1)