PROGRAMMING MANUAL • PH5

 - Mk II AIR INTAKE EMERGENCY SHUT-OFF VALVE 

L6533 

 

 

ECN 1-2408

 

L6533_Rev1

 

5

 

 

5.1

 

For On-Highway Vehicles with Variable Engine Speed 

1.

 

Determine desired Trip Speed 

 

Pacbrake recommends 30% above Rated Engine RPM 

2.

 

Insert fuse into     F1     in Mode Selection Box. Light will exhibit constant rapid flash interrupted by single pulse* 

3.

 

Start engine and raise engine speed to Input Speed 

 

half of desired trip speed

 

 hold constant 

4.

 

Push and release switch to shut down engine

 and save Input Speed. Light will become solidly lit. 

5.

 

When light extinguishes, push and release switch 4 times to set Trip Speed to double Input Speed 

6.

 

Light will indicate programming has been saved correctly by flashing 4 times. 

7.

 

Remove fuse from     F1     in Mode Selection Box to exit Programming Mode. Document Trip Speed for future 
reference.  

Secondary Trip Speed (If applicable): 

Provide power to Secondary Trip Speed Input and repeat above procedure to Program Secondary Trip Speed.  
For use as an anti-theft device, it is recommended to set the Trip speed to idle RPM + 10%. In Step 5, press the 
switch 1 time to set the Trip Speed to Input Speed +10%. Light will flash 1 time as confirmation in Step 6. 

5.2

 

For Stationary Engines with Constant Operating Speed 

1.

 

Determine desired Trip Speed 

2.

 

Insert fuse into     F1     in Mode Selection Box. Light will exhibit constant rapid flash interrupted by single pulse* 

3.

 

Start engine and allow it to run at constant operating speed 

4.

 

Push and release switch to shut down engine

 and save Input Speed. Light will become solidly lit 

5.

 

When light extinguishes, choose desired Overspeed Margin from below to set your Trip Speed: 

 

Push & release switch 1 time 

 

 

 Operating Speed + 10% 

 

Push & release switch 2 times 

 Operating Speed + 20% 

 

Push & release switch 3 times 

 Operating Speed + 30% 

6.

 

Light will indicate programming has been saved correctly by flashing the same number of times the switch was 
pressed 

7.

 

Remove fuse from     F1     on Mode Selection Box to exit Programming Mode. Document Trip Speed for future 
reference. 

Secondary Trip Speed (If applicable): 

Provide power to Secondary Trip Speed Input and repeat above procedure to program Secondary Trip Speed 

NOTE

: Table below demonstrates a simple example of programming your system.

 

Input Speed 

 Switch

 

Presses 

Overspeed Margin 

Trip Speed 

Margin 

RPM 

1000 

+ 10% 

+ 100 

1100 

1000 

+ 20% 

+ 200 

1200 

1000 

+ 30% 

+ 300 

1300 

1000 

Double 

+ 1000 

2000 

*Li

ght will exhibit ‘double pulse’ if Secondary Trip Speed is active

 

 Automatic overspeed protection is disabled during Programming Mode therefore engine shut down is forced on switch push as precautionary measure to 

guard against possible emergency situation.

 