background image

INSTALLATION MANUAL - INSERT TITLE HERE, L1234 

PG 3 

BASIC INDEPENDENT AIR SPRING ACTIVATION KIT - HP10098

PG  3

L5904

COMPRESSOR AIR INTAKE FILTER

Locate the air intake filter housing, barbed fitting and 6

' length  

 

 

of blue nylon hose provided in kit. Choose a location to mount  

 

the filter housing within 6

' of the compressor, the housing re- 

 

quires a 1/2” hole for mounting, the location must also provide 

 

 

clean dry air. Secure the barbed fitting to the filter housing, 

 

 

connect the nylon hose to the barbed fitting, install the housing 

 

 

into the mounting hole. Route the nylon hose to the inlet fitting at 

 

 

the compressor, secure the hose with tie-straps provided. 

 

                            

                                         

                                                                               

ELECTRICAL CONNECTIONS

5

 

Provided in the kit is a pre-wired relay receptacle to make this 

  

part of the installation easy. Find a convenient location close to    

 

the positive battery terminal to mount the relay receptacle. Using 

 

the self tapping screw provided, secure the relay receptacle and 

 

install the relay provided.

                                                                                           

       
        

6

         

Locate either one of the two red 12 gauge wires of the relay 

 

 

harness. Cut to length and connect the 30 amp fused link. 

 

Connect the 30 amp fused link to the positive terminal of the 

 

battery. Locate the second red 12 gauge wire and route to the

 

 

compressor. Cut to length and crimp on the supplied blue butt  

 

 

connector, then connect to the red compressor wire. Locate the    

 

black wire of the compressor and connect to a good chassis  

 

 

ground or the negative battery terminal. Heat the 

 

connector’s to provide a water tight seal.

7

 

Locate the 16 gauge red with white strip and the white wire of the  

 

relay harness. Route these two wires into the cab through the  

 

firewall boot. Connect the red with white strip wire to the 5 amp 

 

 

inline fuse provided, then to a 12 volt ignition power source using 

 

 

the “T” tap connector provided. Test the ignition power source 

 

 

with a volt meter prior to attaching the “T” tap. Some ignition 

 

 

circuits are less than 12 volts which may not be enough to acti-

 

 

vate the relay coil. This wire can be connected through an ON/ 

 

OFF switch to override the compressor activation, should the  

 

customer prefer this option. (Switch not provided in the kit,  

 

available separately)

 

 Heat the butt connector’s to provide a water tight seal.

4

5

6

7

Отзывы: