background image

 

INSTALLATION AND OPERATION MANUAL         

      

                                                                    

 

PAC HEAT RECOVERY WATER HEATER 

 
 
 
 
 

Figure 

 

4 : 

 

PAC

 

Fre-Heater  Model  

 

AL-1002P, AL-1002PS 

 
 

      

 

 

          

Front

   

 

 

 

                                 

 Side 

 
 

       

 

 

  

 

 Back  

 

 

       

 

      Suspension

 

 
 
 

 
 
 
 
 

7

Содержание AL

Страница 1: ......

Страница 2: ...s are rated for a maximum working pressure of 400 psi PAC have a placement for supporting heater by the placement of this element located in the under of the tank The placement of this element allows...

Страница 3: ...eater should be located inside If it is necessary to locate the Fre Heater outside it must be under a cover The Fre Heater must be protected from water dripping or spraying or in any way collecting on...

Страница 4: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 1 PAC Fre heater Model AL 0252P Front Side Back Suspension 4...

Страница 5: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 2 PAC Fre Heater Model AL 0502P AL 0502PS Front Side Back Suspension 5...

Страница 6: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 3 PAC Fre Heater Model AL 0752P AL 0752PS Front Side Back Suspension 6...

Страница 7: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 4 PAC Fre Heater Model AL 1002P AL 1002PS Front Side Back Suspension 7...

Страница 8: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 5 PAC Fre Heater Model AL 1502P AL 1502PS Front Side Back Suspension 8...

Страница 9: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 6 PAC Connections Model AL 0252P 9...

Страница 10: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 7 PAC Connections Model AL 0502P Figure 8 PAC Connections Model AL 0502PS 10...

Страница 11: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 9 PAC Connections Model AL 0752P Figure 10 PAC Connections Model AL 0752PS 11...

Страница 12: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 11 PAC Connections Model AL 1002P Figure 12 PAC Connections Model AL 1002PS 12...

Страница 13: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 13 PAC Connections Model AL 1502P Figure 13 PAC Connections Model AL 1502PS 13...

Страница 14: ...e temperature relief valve has been installed by the manufacturer and should not be removed This valve should be provided with a 3 4 drain line oriented so that any discharge from the valve will exit...

Страница 15: ...be running Consult a plumbing supply house for a hot water circulating pump suitable for your particular installation All pumps used in a Fre Heater water circulation system must be suitable for pota...

Страница 16: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 15 Installing PAC Fre Heater through one circuit into another Figure 16 Installing PAC Fre Heater in parallel series 16...

Страница 17: ...y question about refrigeration line sizing the equipment manufacturer s recommendation should be followed In most instances refrigeration line runs of over 16 metres should not be used If they are par...

Страница 18: ...geration unit When making multiple Fre Heater circuit connections to a single refrigeration unit the piping to the Fre Heater circuits should be in parallel Series through one circuit into another pip...

Страница 19: ...cooling fan must be installed on the compressor if the condenser fan is cycled to maintain head pressure Consult the compressor manufacturer for their recommendation if you are in doubt of sufficient...

Страница 20: ...AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 17 Installing Refrigerant Charge with Air Condition Figure 18 Typical Refrigeration Connections for Single Refrigeration Unit and Single Circ...

Страница 21: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 18 Typical Dual Refrigeration Unit Piping 21...

Страница 22: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 19 Fre Heater Location with Hot Gas Defrost Valve Oil Separator and or Discharge Muffler in System 22...

Страница 23: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 20 Installing Refrigerant Charge by Heat Exchanger 23...

Страница 24: ...y operating it to see that it will freely flow water should it be required to do so If there is any doubt that it will not function properly replace it 3 Check all water fittings valves etc to be sure...

Страница 25: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Efficiency Figure 21 Result of Electric Power of Compressor with out PAC 25...

Страница 26: ...HEATER Figure 22 Result of Electric Power of Air condition and Temperature of Refrigerant by PAC setting have water in but not flow out Figure 23 Result of Electric Power of Air condition and Tempera...

Страница 27: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER Figure 24 Temperature of water flow out from the Mueller 27...

Страница 28: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER APPENDIX THE COLUMN TOWER 28...

Страница 29: ...5 36 Celsius then there are some water flow out from Pressure Relief Valve You should adapt to Pressure Relief Valve for flow out the water that higher temperature If the temperature in PAC is more th...

Страница 30: ...INSTALLATION AND OPERATION MANUAL PAC HEAT RECOVERY WATER HEATER 30...