MAINTENANCE:  

To obtain best efficiency

and longest periods of trouble-free operation

the air supply must be kept clean as dirt is the

most  common  cause  of  erratic  regulator

operation. Only a few parts require occasional

replacement most troubles can be cured and

prevented by a thorough and careful cleaning

procedure. To  clean  it  is  not  necessary  to

remove  unit  from  its  piping  or  line. At  the

bottom of the bowl is a manual drain valve

which should be periodically opened particu-

larly when sediment is visible in bowl.

DISASSEMBLY FOR CLEANING:

Depressurize  the  air  line,  unscrew  and

remove  the  bowl.  Unscrew  filter  element

and  let  down  bottom  disc,  filter,  top  disc,

spring  and  plunger.  Note  orientation  of

plunger and top disc. Clean filter element

and assemble parts as removed. Make sure

“o” ring seal for bowl is in place. Tighten the

filter element and bowl hand tight.

CLEANING:

For best results clean parts with soap water.

After cleaning blow out parts including body

of unit with compressed air. The bronze filter

should be blown out from the inside,blocking

one end with folded rag.  

Plastic bowl must

be cleaned with household  soap only!

R-75  Regulator and Filter

Installation, 

Operation

and Maintenance

WARNING! 

The  polycarbonate  plastic

material  used  to  manufacture  the  plastic

bowls  may  be  attacked  by  certain

chemicals. Do not use this filter system with

air supplied by a compressor lubricated with

synthetic oils or oils containing phosphate

esters or chlorinated hydrocarbons. These

oils  can  carry  over  into  the  air  lines  and

chemically attack and possibly rupture the

bowl.    Also,  do  not  expose  the  bowl  to

materials  such  as  carbon  tetrachloride,

trichlorethylene,  acetone  paint  thinner,

cleaning fluids, or other harmful materials,

for they too will cause the plastic to craze

and/or  rupture.  For  use  in  environments

where  any  of  these  chemicals  may  be

present, consult the factory.

INSTALLATION:  

Install in vertical position

with  air  supply  connected  to  the 

in

port

stamped on body of unit. Before piping-in,

blow  out  line  to  remove  scale  and  other

foreign  matter.  If  pipe  compound  is  used

apply only to male threads and just enough

to make tight connections.

WARNING:   

Maximum  primary  air

pressure  135  p.s.i.  Temperature

Range  40°F  to  125°F.  Accurate

regulation between 2 and 60 p.s.i. De-

pressurize regulator before servicing.

AIR PRESSURE

ADJUSTING KNOB

PULL KNOB TO

REGULATE - PUSH

KNOB TO LOCK

AIR IN

BRONZE FILTER

PLASTIC BOWL

MANUAL MOISTURE

DRAIN

AIR OUT

PUSH UP VALVE TO
DRAIN MOISTURE  -
ATTACH HOSE TO
NIPPLE TO DIRECT
WATER TO CONTAINER.

Содержание DC600R

Страница 1: ...nk you for purchasing The Paasche DC600R Airbrush Compressor Please read this Instruction Manual carefully before operating the compressor to get the best performance INSTRUCTION MANUAL INSTRUCTIONS AND PARTS DC600R 11 01 2011 ...

Страница 2: ...lug in compressor turn on the switch and the air compressor will start pumping air The gauge will show the max pressure and you can adjust the working pressure by adjusting the pressure regulator knob 2 Checking for air leaks After turning the compressor on wait for the tank to fill and the compressor to turn off auto stop function Then check the needle of the pressure gauge If the needle on the g...

Страница 3: ... connecting the compressor check that the main voltage complies with the electrical characteristics of the motor 3 Please follow local electrical and safety rules Electric plug must be grounded 4 Never leave the compressor exposed to dust acids vapors explosive or flammable gasses or atmospheric agents rain sun fog snow 5 The vacuum pump must be used in suitable environments well ventilated with a...

Страница 4: ...llation Operation and Maintenance WARNING The polycarbonate plastic material used to manufacture the plastic bowls may be attacked by certain chemicals Do not use this filter system with air supplied by a compressor lubricated with synthetic oils or oils containing phosphate esters or chlorinated hydrocarbons These oils can carry over into the air lines and chemically attack and possibly rupture t...

Отзывы: