background image

 
 
 
 

Latest Update: 20/04/2018

 

 

2
 

DIMENSIONAL DRAWING 

 

 
 
INSTRUCTIONS 
 
SELECTION 

This product is to be used with clean, fresh water, or water slightly additivated with ordinary detergents. For use involving harsh or even 
corrosive fluids, always ask PA Technical department first. Appropriate filtration should be installed when using unclean fluids.  
To  select  the  right  valve,  always  take  in  consideration  rated  running  data  of  the  system  (rated  pressure,  max.  flow  rate  and  max. 
temperature). In no case shall the system pressure exceed the 

permissible pressure  

marked on the valve. 

 

INSTALLATION 

On a water heating machine, fit the valve before

 the heat generator

. This product is bound to be incorporated on a finished machine. 

On a water heater, it is necessary  to mount accessories that limit the accidental increase of fluid temperature. 

Always install a safety valve to protect  the pressurized outlet channel. 

Select the right nozzle size, which allows a regular discharge into bypass of at least 5% of the total flow rate of the system. This will 
keep a constant pressure setting and prevent pressure spikes at shut off which could damage the system. 
By nozzle wearout, the pressure drops. When replacing the nozzle, reset the system to the original pressure level. 
 

OPERATION 

The  valve  regulates    the  max.  system  pressure  through  a  piston,  which  acts  on  a  cone  that,  normally  positioned,  closes  the  bypass 
opening. A check valve cuts out the delivery section, the pressure of which controls the piston drive. 
All adjustments should be carried out when the system is in operation and the nozzle is working. 

IMPORTANT: The nut (pos.15) must never be removed, as it is a mechanical safety device that limits the max pressure and 
prevents serious damage to persons and things. 

 

DISCHARGE SYSTEM AND WATER ADDUCTION 

The bypass conduct shall discharge outside of the machine or into a tank, but never directly into intake conduct. In case, it is advisable 
to install a baffled tank. 
 
 
 

Содержание VB 450-200

Страница 1: ...x pressure increase at system shut off is a percent value of calibration pressure When it occurs the valve is set in operation and the whole fluid is diverted into bybass 3 The pressure decrease at bypass reset is a percent value of calibration pressure It indicates the pressure drop required for the valve to restore pressure in the system Instruction Maintenance Installation Spare Parts Booklet F...

Страница 2: ...ssurized outlet channel Select the right nozzle size which allows a regular discharge into bypass of at least 5 of the total flow rate of the system This will keep a constant pressure setting and prevent pressure spikes at shut off which could damage the system By nozzle wearout the pressure drops When replacing the nozzle reset the system to the original pressure level OPERATION The valve regulat...

Страница 3: ...ect use follow the instructions given in this booklet and re print them on the Use and Maintenace Manual of the machine Make sure that you are given the original Declaration of Conformity for the chosen item This booklet is applicable for all unloader valves type VB 450 200 300 MAINTENANCE All maintenace operations must be carried out by qualified personnel only ROUTINE every 400 hours of operatio...

Страница 4: ...4003 51R Shutter M 12 1 3 10 10 3206 08R O ring 2 62x28 25 mm Ni85 1 10 11 60 4005 31R Bushing 1 3 12 10 4084 00R Back up ring 16x20 5x2mm 1 5 13 10 3181 20R O ring 2 62x15 88 mm 1 10 14 60 4007 31R Bushing 1 3 15 10 3246 05R O ring 3 53x28 17 mm 1 5 16 10 4096 00R Back up ring 28x34x2mm 1 5 17 60 4004 51R Piston M 12 1 3 18 14 7465 00R Ball 1 2 Sst 1 5 19 60 4009 31R Piston holder 1 1 20 60 4010 ...

Отзывы: