background image

 

ATEX HYDROKINETIC ROTATING CLEANING HEADS 

SAFETY NOTE 

SN01 

Rev. 00 

Date 22/04/2020 

Pag. 3 of 10 

 
 

1.

 

INTRODUCTION 

 
PLEASE  READ  THE  FOLLOWING  INSTRUCTIONS  CAREFULLY  BEFORE  INSTALLING  ANY  EC-MARKED  PART  (CLEANING 
HEAD),  ACCORDING  TO  THE  ATEX  PARTS  DIRECTIVE  2014/34/EU  IN  A  POTENTIALLY  EXPLOSIVE  ATMOSPHERE  AS 
DEFINED IN THE ATEX WORK ENVIRONMENT DIRECTIVE 99/92/EC
. This manual must be brought to the attention of 
the personnel working with the head, and must be illustrated to the personnel qualified for maintenance and repair of 
the head. Any substantial modification to the head will not be allowed. 
 
Any  substantial modification must  be  authorized  by P.A.  S.p.A. (for  a broader definition  of  substantial modification, 
please see maintenance manual). 
 

2.

 

DESCRIPTION OF THE PRODUCT 

 

2.1

 

CLASSIFICATION & MARKING 

 
The  unequivocal  identification  of  the  equipmet  is  to  be  verified  by  the  data  imprinted  on  the  body  and  by  the 
declaration  of  conformity  attesting  that  the  tool  was  subjected  to  a  conformity  test  according  to  directive 
2014/34/EU, annex VIII, requiring for a technical file to be sent to a Certification Body. 
 
The marking of the cleaning head is: 
 

 

2460

    

II 1 G Ex h IIC T6...T4 Ga 

II 1 D Ex h IIIC T85°C...T135°C Da 

Ta: 0°C / +90°C 

 

Presafe 20 ATEX 319809 

 
where: 

 

Symbol 2460: DNV GL Presafe AS Certification Body 

 

Symbol CE Ex: in accordance with directive 2014/34/EU 

 

Group II: suitable on surface 

 

Category 1: suitable in zones 0 - 1 – 2 for gas and in zone 20 – 21 -22 for dust 

 

Substance type: G (gas) and D (dust) 

 

Specific type of protection: “Ex h” (construction safety) 

 

Group of gas/dust: IIC (gas) and IIIC (dust) 

 

Temperature Class/Max surface temperature: T6…T4 (gas) and T85°C…T135°C (dust) (see note 1) 

 

EPL: Ga (gas) and Da (dust) 

 

Ambient Temperature: 0 ÷ +90 °C 

 

Certificate Number: Presafe 20 ATEX 319809 

 

Additional marking on equipment: material of the Seals: E – N – K – V (see note 2) 

 
The measures of prevention and protection described in this manual do not determine the level of safety required if 
the  heads  will  not  be  used  according  to  the  provisional  use,  nor  if  they  were  not  installed  and  subjected  to 
maintenance according to the terms of use or appropriate requirements.  

Содержание A42R-316-360

Страница 1: ...la NSF CLEANING HEAD Stainless steel construction Suitable for utilization in food industry This is a self propelled tank cleaning head when the flow rate increases the head rotates faster Cleaning of interior surfaces of tanks and drums Reduced flow high pressure high cleaning impact Orbital coverage of interior surfaces Small spray turret that fits through reduced tank opening Rotating speed ind...

Страница 2: ... 32 195 F 1 8 NPT ATTACCO ALIMENTAZIONE ACQUA INLET CONNECTION SIZE ATTACCO UGELLI 2 o 4 NOZZLES CONNECTION 2 OR 4 PESO WEIGHT SPECIFICHE TECNICHE PRESSIONE NOMINALE RATED PRESSURE PORTATA FLOW RATE PRESSIONE CONSENTITA PERMISSIBLE PRESSURE TEMPERATURA MASSIMA ACQUA MAX WORKING TEMPERATURE 40 140 bar 4 14 MPa 580 2000 psi TECHNICAL SPECIFICATIONS TEMPO PER UN CICLO COMPLETO DI LAVAGGIO 47 GIRI DEL...

Страница 3: ... SAFETY NOTE SN01 Rev 00 Date 22 04 2020 Pag 1 of 10 DOCUMENT REVISION REV DATE MODIFICATION 00 22 04 2020 First issue PREPARED BY RGQ Michele QUATTRONE SIGNATURE CHECKED BY DUT Fabio PEDRONI SIGNATURE APPROVED BY AD Alberto BENETTI SIGNATURE ...

Страница 4: ...5 USE WORKING 6 3 5 1 WORKING ADJUSTMENT 6 3 5 2 SUITABLE NON SUITABLE USE 7 3 5 3 DANGEROUS AREAS 7 3 5 4 DANGER POSSIBLE RISKS 7 3 5 5 PPE PERSONAL PROTECTIVE EQUIPMENT PROCEDURES TRAINING 8 3 6 SYSTEM PROCEDURES 9 3 6 1 TOOLS MACHINERY 9 3 6 2 LOAD UNLOAD 9 3 6 3 START STOP 9 3 7 INSPECTION ORDINARY EXTRAORDINARY MAINTENANCE SERVICE CLEANING 9 3 7 1 PRECAUTIONS 9 3 7 2 ORDINARY MAINTENANCE AND ...

Страница 5: ... subjected to a conformity test according to directive 2014 34 EU annex VIII requiring for a technical file to be sent to a Certification Body The marking of the cleaning head is 2460 II 1 G Ex h IIC T6 T4 Ga II 1 D Ex h IIIC T85 C T135 C Da Ta 0 C 90 C Presafe 20 ATEX 319809 where Symbol 2460 DNV GL Presafe AS Certification Body Symbol CE Ex in accordance with directive 2014 34 EU Group II suitab...

Страница 6: ...when installed in a potentially explosive environment The appliance in question grants that potential sources of priming are not activated in normal functioning and even in case of foreseeable and rare failure or malfunction Breakage or failure to the appliance can happen In that case it is necessary to check the causes of failure When these are traced down to the appliance they must be removed No...

Страница 7: ...subject to shock impacts tumbles deteriorment and other damaging which could compromise the function of the head Any eventual damage must be immediately communicated to P A S p A for assessment 3 2 INSTALLATION 3 2 1 WARNING Each installation or reinstallation must be performed by qualified personnel duly trained and informed on the related risks even concerning the instructions of this document W...

Страница 8: ...ection grade minimum IP54 for Gas and IP6X for powders Insert the connection tubes entry and exit following a good technique and using acknowledged components adopting the foreseen clamping instructions During the connection of the tubes make an electrical earth link up with a minimum cable size 4mm observing the prescribed terms for equipotential connections Inspection after installation to be ca...

Страница 9: ...nsidered in the planning stage in view of the safety measures adopted The Company P A S p A declines all responsibility for damage to persons animals or things derived by an improper use of the apparatus a o the non observance of the dispositions contained in the present manual 3 5 3 DANGEROUS AREAS Particular attention has to be reserved to any area potentially explosive around the head and also ...

Страница 10: ...ated back pressure to the nozzles acts negatively on the head compromising the set calibration The nozzles must be exempt from back pressure They must not be blocked and no flow from the nozzles towards the inside of the head is permitted Ambient risks Ambient conditions different than those specified can cause a danger source They can cause dangerous service conditions with relation to the proces...

Страница 11: ... certify that the operator is opportunely instructed to carry out all the safety procedures hygiene in the work areas according to the protocol in order to avoid any eventual risks deriving from the operations mentioned above 3 7 2 ORDINARY MAINTENANCE AND CLEANING After a normal daily usage wash the inside of the head with clean water without any additives Carry out an internal check after 100 ho...

Страница 12: ...tenance replacement the removal of the head from the application is permitted only when the apparatus is not under pressure and in the absence of a potential explosive atmosphere Before reusing or reutilizing the head after washes general maintenance or any other necessary operation follow the warnings as seen on paragraph 3 1 1 of this safety note After reinstalling the device and before placing ...

Страница 13: ... 1 2 19 80 0859 60R Anello rasamento Ai316 1 3 20 80 0858 60R Perno M10 inox Ai316 1 1 21 80 0821 60R Satellite z 24 Ai316 9 3 22 80 0822 84R Boccola Di 8x12 mm 9 3 23 80 0833 21R Portasatelliti intermedio completo 2 1 24 80 0809 60R Corpo 3 stadi Ai316 1 1 25 80 0213 84R Perno rasamento plast 1 10 26 80 0832 21R Portasatelliti completo sp rasam 1 1 27 80 0808 60R Spina 3x24 5mm Ai316 1 3 28 16 19...

Страница 14: ...59 60R Shim ring Sst Ai316 1 3 20 80 0858 60R Pin M10 Ai 316 Sst 1 1 21 80 0821 60R Planetary gear z 24 Ai316 9 3 22 80 0822 84R Bushing 8x12mm 9 3 23 80 0833 21R Plan gear holder 3 pins gear Sst 2 1 24 80 0809 60R Ring gear z 60 3 stage cleaner sst 1 1 25 80 0213 84R Shim pin plast 1 10 26 80 0832 21R Plan gear holder 3 pins Sst 1 pin 1 1 27 80 0808 60R Parallel pin 3x24 5mm Ai316 1 3 28 16 1909 ...

Страница 15: ......

Страница 16: ...P A S p A Via Milano 13 42048 Rubiera Reggio Emilia Italy Tel 39 0522 623611 Fax 39 0522 629600 info pa etl it www pa etl it COMPANY WITH QUALITY MANAGEMENT SYSTEM CERTIFIED BY DNV ISO 9001 ...

Отзывы: