P3 International Kill A Watt Скачать руководство пользователя страница 19

Содержание Kill A Watt

Страница 1: ...Kill A Watt Wireless with Carbon Footprint Meter P4225 and P4220 Kill A Watt sans fil avec capteur d empreinte au carbone P4225 et P4220 ...

Страница 2: ...ning the wireless sensor display panel 8 7 2 Starting up the sensors 8 8 Display and control elements 9 8 1 Display of the wireless sensor display panel 9 8 2 Control elements 10 9 Operation 11 9 1 The key I 11 9 1 1 Short press of the button Displaying the costs for various time periods 11 9 1 2 Long press of the button Price per kWh and the CO2 equivalent 13 9 2 The key Data 14 9 2 1 Short press...

Страница 3: ...nce and cleaning 21 14 Handling 22 15 Disposal 22 16 Technical specifications 23 16 1 Wireless sensor display panel 23 16 2 Wireless sensor unit 23 17 FCC Information 24 17 1 FCC Information Wireless sensor display panel 24 17 2 FCC Information Wireless sensor unit 25 18 Service and warranty information 26 3 ...

Страница 4: ...re reserved 1 1 Intended use Kill a Watt is an energy measurement system consisting of a wireless sensor display panel and up to eight energy sensors The energy sensors send their measurement values via radio signal to the wireless sensor display panel The energy measurement system is only to be operated in dry interior rooms Manufacturer assumes no responsibility for incorrectly displayed or meas...

Страница 5: ...l Wireless sensor unit Operating instructions 3 Terminology A An exclamation mark in a triangle indicates important instruc tions in the operating manual which must be observed under all circumstances co The hand icon points to special tips and instructions on using the product 5 ...

Страница 6: ...y unit Values are transmitted from the wireless sensor unit to the display unit via radio signal 4 2 Wireless sensor unit All physical values for cost calculation are determined in the wireless sensor unit Current Voltage Phase angle Effective power Power consumption since previous data transmission Accumulated power consumption Data is transmitted cyclically The wireless sensor unit is already ta...

Страница 7: ...other areas Do not use the unit if there is damage to the housing Do not subject the device to temperatures below 32 F 0 C or above 158 F 70 C For safety and licensing reasons FCC it is not permitted to convert or modify the product Do not leave the packaging material laying around Plastic foil and bags polystyrene parts etc are dangerous in the hands of children This product is not a toy It conta...

Страница 8: ...es in order to prevent damage caused by leaking batteries rechargeable batteries 7 Peparation for operation commissioning 7 1 Commissioning the wireless sensor display panel Open the battery compartment at the back of the wireless sensor display panel Insert three batteries AA cells into the battery compartment observing correct polarity Use alkaline batteries if possible Although you can use rech...

Страница 9: ...sed time Legend for Symbols Forecast Period Time periods for the displayed fore cast value Sensor address Sensor address for the data shown on the display Energy costs CO emission Energy costs in or CO2 emission in Lbs Metered Values Physical measurement data Used energy current voltage power factor Reception status progress indicator Progress indicator time between two measurement value transmiss...

Страница 10: ...ht can also be used as value input buttons depending on the context The respective buttons can be pressed shortly to recall certain values and can be used for configuration with long press Key Cost forecast for various time periods Key Data Measurement value button Display of measurement values for a sensor Key Sensor Sensor button changes the display between individual sensors switches Auto funct...

Страница 11: ...r sensor encompassing values 0 Short and long pressing of the button selects different functions Short 3 s Long 3 s 9 1 The key 9 1 1 Short press of the button Displaying the costs for various time periods A short press of the button switches between the costs for different time periods This is shown in detail in the following diagram Basically all other buttons function in the same way 1 1 ...

Страница 12: ...one after the other Total costs for the displayed sensor or for all sensors together the display shows or Lbs above the text Total Forecasted costs for the day Forecasted costs for the week Forecasted costs for the month Forecasted costs for the year 12 ...

Страница 13: ...ith keys Data and Sensor buttons 2 and 3 Confirm the entry with the button Now enter the respective CO2 equivalent lbs kWh A default value is de fined here as well 1 669 lbs kWh Confirm the entry with the button Finally define the value that is to be permanently displayed on the large display Costs display shows dEF or CO2 emission display shows dEF Lbs P Exit setup mode by pressing the key again ...

Страница 14: ...longer than three seconds The display shows the number of the sensor for which the data is to be deleted The area for displaying the measurement values shows a flash ing and all symbols for dimensional units Pressing the button for another extended period then closes the deletion function and the display returns back to normal mode You can abort delete mode by pressing any key briefly If no entry ...

Страница 15: ...each mode is ended and normal mode appears on the display If no more memory locations are free the large seven segment display shows In order to add a new sensor an old one must be deleted in this case You can abort teach mode by pressing any key shortly If no key press is made for 20s teach mode is aborted automatically Deleting Call up the display for the sensor to be deleted with the sensor key...

Страница 16: ... consumption of selected Sensor for the week Forecast for a month Estimated power consumption of selected Sensor for the month Forecast for a year Estimated power consumption of selected Sensor for the year c0 When auto function is activated the display content automati cally changes and metering data for each sensor successively is displayed When pressing the data key once actual power con sumpti...

Страница 17: ...l Sensors for the year Example Sensor 3 is chosen and in section Metered values the actual current consumption is displayed When changing to all sensors no sensor number is shown in the dis play sum of all sensors by pressing the key Sensor a value for the cumulated or estimated power consumption of all sensors is displayed What is displayed in the section Elapsed time depending on the se lected s...

Страница 18: ...our batteries need replacing Always replace the whole set of batteries Never mix new batteries with used batteries Always use three batteries of the same type by the same manu facturer Do not mix batteries with rechargeable batteries As already mentioned you can use rechargeable batteries how ever durability is appreciably lower than with batteries Follow the instructions in chapter 7 1 to change ...

Страница 19: ...are interfering with the radio reception Relocate the sensors and the wireless sensor display panel Another transmitter on the same or a neighboring frequency is interfering with the radio signal from the sensors If possible set other devices to a different fre quency The wireless sensor unit is not inserted into the socket The socket inserted in the wireless sensor unit has no voltage applied Pow...

Страница 20: ...el ceilings coated layered insulation glass panes vehicles trees bushes earth rocks proximity to metal conductive objects e g radiators proximity to the human body broadband disturbances e g in residential area Cordless tele phones mobile phones radio headphones radio loudspeakers radio weather stations baby monitors etc proximity to electric motors transformers switching power sup plies or comput...

Страница 21: ...ing servicing or repair work There are no user serviceable parts on the inside do not open the device Repairs may only be carried out by a specialist who is familiar with the associated hazards and relevant regulations applying to the device 13 2 Cleaning Dust can be removed very easily with a vacuum cleaner and a soft clean brush Hold the vacuum cleaner nozzle close to the device avoid touch ing ...

Страница 22: ...inity of ma chines or speakers Never use the product immediately if it has been taken from a cold area to a warm area This causes condensation which could destroy the de vice under certain circumstances Wait until the devices have reached room temperature This can take several hours Choose a safe and stable location for the wireless sensor display panel and ensure that the wireless sensor display ...

Страница 23: ...nch Approval FCC 16 2 Wireless sensor unit Operating voltage Max operating voltage Load current Max connection load Measurement category Pollution degree Data transmission Transmission frequency Modulation type Transmission power sent Ambient temperature Relative humidity Altitude Connections IP degree of protection Dimensions 1N x H x D Approval FCC Safety FCC Part 15 Subpart B 115 V 60 Hz 125 V ...

Страница 24: ... DoC Statement This device trade name P3 model number ECC100D US complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The responsible party for this device compliance is P3 INTERNATIONAL CORPORATION...

Страница 25: ...ful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiv...

Страница 26: ...ect or accident or as a result of unauthorized alterations or repairs to the product This warranty is void if the serial number if any has been removed altered or defaced This warranty is in lieu of all warranties expressed or implied including the implied warranties of merchantability and fitness for a particular pur pose which are expressly excluded or disclaimed P3 shall not be respon sible for...

Страница 27: ...If you experience difficulty in the operation of your unit or if your unit requires repair please contact P3 INTERNATIONAL CORPORATION 27 ...

Страница 28: ...oduced per Kilowatt Hour of electricity generated Most electric utilities publish this information and it can be found in reference material or from the customer service department Use one of these methods to determine the rate for your utility and set it into the unit as per the operating instructions Methods 1 From your utility Call write or email the customer service department for your electri...

Отзывы: