P3 International Kill A Watt PS P4320 Скачать руководство пользователя страница 7

appliance power consumption (in Watts) with the currently measured power factor (in %), the maximum 
measured watts/PF (indicated by the MAX icon) and the minimum measured watts/PF (indicated by the 
MIN icon). The display will return to the currently measured values after a few seconds. Pressing and 
holding the Watt/PF key for a few seconds will delete the memorized MAX/MIN values. The measured 
power consumption is the sum of all connected appliances.

 

3. KWH/Leakge 

(leakage)

 key: Pressing the KWH/Leakge key repeatedly will cycle through displaying the 

cumulative appliance power consumption (in Kilowatt Hours) since last reset with the currently 
measured leakage current (in milliamps), the maximum measured leakage current (indicated by the 
MAX icon) and the minimum measured leakage current (indicated by the MIN icon). The display will 
return to the currently measured values after a few seconds. Pressing and holding the KWH/Leakge key 
for a few seconds will delete the memorized MAX/MIN values for leakage current. There are no 
MAX/MIN values for KWH as it is a cumulative value. 

IF YOU NOTE SIGNIFICANT LEAKAGE 

CURRENT MEASUREMENTS STOP USING THE CONNECTED APPLIANCE(S) IMMEDIATELY AND 
HAVE IT SERVICED 

4. Elapsed 

Time 

key: Pressing the Elapsed time key repeatedly will cycle through displaying the elapsed 

time of energy usage in Days:Hours and Hours:Minutes. Pressing and holding the Elapsed Time key for 
a few seconds will reset the elapsed time counter to zero and will clear cumulative KWH measurement. 
Be sure you have taken note of KWH measurements (if desired) before you reset as they cannot be 
retrieved once reset.

 

Retained Measurements: 

1.  When power to the Kill A Watt™ 

PS

 is interrupted, the display will go blank and the unit will stop 

measuring consumption and elapsed time. However all accumulated measurements including KWH and 
Elapsed Time will be retained. 

2.  This allows the user to take measurements anywhere and relocate the unit to a more convenient 

location to read the display. When the unit is plugged back in, the display will become active and will 
flash as an indicator of power interruption. Press any key momentarily to cancel the flashing. The 
accumulated KWH measurement can be retrieved by using the KWH/Leakge key. The accumulated 
elapsed time can be retrieved by using the Elapsed Time key. Data should be retrieved immediately as 
the Elapsed Time counter will restart and potentially skew the data as time with no load elapses. 

3. 

Pressing and holding the Elapsed Time key for a few seconds will reset the elapsed time counter to 
zero and will clear cumulative KWH measurement. Be sure you have taken note of KWH measurements 
(if desired) before you reset as they cannot be retrieved once reset.

 

Protection Functions: 

1. 

Max. Amps

 switch: This switch on the control panel allows the user to optionally select the maximum 

current (Amps) the unit will deliver to the attached appliances without automatically shutting off. Use a 
small screwdriver to select 2A, 5A, 10A or 15A (factory default). 

Setting Procedure: 

a.  Use a small screwdriver to select 15A (factory default setting). 

b.  Connect all appliances to the unit and operate appliances at their highest level. 

c.  Press the Volt/Amp key to observe the current value (Amps) consumed by appliances. 

d.  Turn off the connected appliances and turn the unit off. 

e.  Use the small screwdriver to set Max. Amps to the next highest value. For example if the LCD 

display indicates your appliances are consuming 6.12 Amps at their highest level, set the Max. 
Amps switch to 10A. In the future, if the attached appliances begin to draw a higher than normal 
load and exceed 10A of current, the unit will go into Over Current Mode (see below), shut off 
power and help protect the connected appliances. 

f.  Resume normal operation. 

2. 

NFB (No Fuse Breaker)

 The NFB will activate when the unit is subject to overload. Press the NFB to 

reset and restart. 

Содержание Kill A Watt PS P4320

Страница 1: ...can protect your valuable electronics and find out what they are actually costing you Simply connect these appliances to the Kill A Watt PS and it will assess how efficient they are while the built in surge protection keeps them safe Advanced features such as over current over voltage and no load detection provide clean safe power to your expensive equipment Check the quality of your power by moni...

Страница 2: ...b wash bowl kitchen sink or laundry tub in a wet basement or near a swimming pool and the like Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the product Any mounting of the product should follow the manufacturer s instructions Ventilation Slots and openings in the cabinet...

Страница 3: ...f liquid has been spilled or objects have fallen into the product If the product has been exposed to rain or water If the product does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician t...

Страница 4: ...stable 2 5 10 or 15A breaker 5 NFB No Fuse Breaker Over Load protection Wall Mount Instructions Optional 1 Use 3 4 inch no 8 screws or similar 2 Space the 2 screws about 9 inches 230mm apart according to the figure Leave about 1 4 inch 5mm of the screw head protruding from the surface 3 Place the unit against the surface with the screw heads fitting into the mounting holes 4 Move the unit downward...

Страница 5: ...l go dark and the NO Load icon will flash on the LCD display THIS IS NORMAL If the attached appliance is then turned on the unit will detect a load the ON key will illuminate and the NO Load indicator on the LCD display will disappear 6 Pressing the Volt Amp key will cycle through currently measured voltage Volts current Amps and Maximum Minimum measured values 7 Pressing the Watt PF Key will cycl...

Страница 6: ... power will not be applied to the outlets Understanding the No Load Function 1 No Load means no electrical load placed on the unit Either there are no appliances connected to the unit or the appliances connected are turned off and are not drawing any stand by power If a connected appliance is turned off but is still drawing stand by power there is still a load placed on the unit The unit will not ...

Страница 7: ...ed Time will be retained 2 This allows the user to take measurements anywhere and relocate the unit to a more convenient location to read the display When the unit is plugged back in the display will become active and will flash as an indicator of power interruption Press any key momentarily to cancel the flashing The accumulated KWH measurement can be retrieved by using the KWH Leakge key The acc...

Страница 8: ...reaker When the current load presented by the connected appliances exceeds 15 Amps the unit will switch to Over Load mode The power will be switched off to the 8 outlets The red LED in the OFF switch will flash The Over Load icon will flash and the audible alarm will sound Remove the appliance s which is causing the over load power draw Then press the OFF key and then the ON key to turn the power ...

Страница 9: ...If condition persists call a qualified technician This is the abnormal voltage too high or too low protection function 5 No Load icon on the LCD display flashes The unit will power on automatically when the load returns This is the no load protection function to reduce the chance electrical shock or damage 6 No Load icon continues to flash when appliances are connected and turned on Increase the n...

Страница 10: ...ion costs shall be borne by the owner and the risk of loss shall be upon the party initiating the transportation All items repaired or replaced thereunder shall be subjected to the same limited warranty for a period of six 6 months from the day P3 ships the repaired or replaced product The warranty does not apply to any product that has been subject to misuse tampering neglect or accident or as a ...

Отзывы: