Changing the cylinder: 

Turn off the regulator and disconnect the regulator from cylinder, allow the heater to control fully before removing 

and replace the cylinder. Do not attempt to remove the regulator while the heater is still running. 

Change LPG cylinder in ample ventilated area, and from any ignition source (candle, cigarettes and so on). 

Maintenance:   

●When the heater is not in use of a period of time, for instance, over the summer, we recommend that it is kept 

covered or replaced in its carton to minimize the accumulation of dust dirt that may occur.   

●Maintenance and cleaning must be carried out with the gas supply turned off and the heater cold. Do not attempt 

to clean the heater while it is in use. 

●Your heater should be checked annually by a qualified person for safe operation and to detect any faults. 

●If any faults are detected in use, stop using the heater and contact your dealer for advice. 

●Periodically clean the exterior and rear cylinder, storage area of your heater to remove dust a lint built-up, which 

may affect operation of the heater. 

●Light vacuuming with a soft brush will remove any dust built-up on the surfaces of the ceramic elements. Do not 

scrape of knock these elements as they may become very fragile with use. 

●Do not abrasive products to clean the heater. 

●Watch the pilot flame while it is in operation. It should burn steadily, if it flickers or is yellow tipped, the heater 

should be checked for correct operation. 

●If any parts need replacement, they must be replaced only with genuine original parts supplied by the manufacturer. 

The use of incorrect or substitute the parts may be dangerous and will void any warranty. 

Do not use wet rag or sprinkling water on the heater while cleaning. This may cause serious problem to the heater. 

Under the circumstance of normal usage, contact our agents to conduct regulator maintenance. 

Leave the heater at a clean and dry area when it is not used. 

 

Operate the heater according to following procedures when electric power is used.

 

The electric heating system is designed with technology of infrared radiation. Even if it is used in an unsealed and 

large size room., heating efficiency will be perfect. Choose different control level for your various demands. 

2)

 

Operation   

f.

 

Make sure plug is normally earthed. Put plug in the socket. 

g.

 

Press switch- to start the top quartz tube. 

h.

 

Press switch- to start the other two quartz tubes. 

i.

 

Press switch- to start all quartz tubes. Heat load reaches to peak. 

j.

 

Turn all switch off after use. Remove the plug from the socket. 

As shown in following Figure. 

 

 

 

 

 

 

 

 

 

 

 

Содержание LQ-HE01

Страница 1: ...Brugermanual Mobile Gasovne LQ HE01 elektrisk gasovn LQ H001A Gasovn L s venligst instruktionerne f r du tager produktet i brug Lavet i P R C...

Страница 2: ...3 28 30 37 BUTANE G30 for 28 30 mbar Propane G31 for 37mbar 28 30 37 mbar BE FR IT LU IE GB GR PT ES CY CZ LV LT SK CH SI UK 13B P 37 Butane G30 Propane G31 og deres blanding 37 mbar PL Model Nr LQ HE...

Страница 3: ...theder 5 ben for gasventilen f r du bruger gasovnen derefter luk for gasventilen efter brug T nd gasovnen F r du tilslutter regulatoren til gasflasken tjek om der er en gummiskive p regulatoren og gum...

Страница 4: ...varsel L s brugermanualen grundigt Den indeholder b de vigtig information om hvordan gasovnen fungerer og om hvordan du sikrer din sikkerhed Brug ikke defekte produkter Vedligehodelse og reparetioner...

Страница 5: ...ge jo mere de bliver brugt Slib ikke p produkterne for at reng re gasovnen Hold je med v geblus flammen mens ovnen er t ndt Den burde br nde st t hvis den flimrer eller har gul spids b r den blive tje...

Страница 6: ...enbord j Sluk ovnen hvis du forlader omr det lad aldrig ovnen v re t ndt n r du sover eller forlader ovnen k Brug altid en tilt nkte ledning stik og kontakt beskyt dem altid fra fugt og vand l Sluk al...

Страница 7: ...User Manual Mobile Gas Heater LQ HE01 electric Gas heater LQ H001A Gas heater Please read the instructions before operating the appliance MADE IN P R C...

Страница 8: ...SE CY CZ EE LV LT MT SK SI BG IS NO TR HR HU RO IT UK 13 28 30 37 BUTANE G30 at 28 30 mbar Propane G31 at 37mbar 28 30 37 mbar BE FR IT LU IE GB GR PT ES CY CZ LV LT SK CH SI UK 13B P 37 Butane G30 P...

Страница 9: ...tap after using Lighting heater Before connecting the regulator to the gas cylinder check whether there is a rubber washer on the regulator and the washer must be in good condition Connect the regulat...

Страница 10: ...o the risk of burns Warning Read the instructions in the manual carefully It has important information both for operation use and for your safety Do not use faulty appliances Maintenance and repairs m...

Страница 11: ...f knock these elements as they may become very fragile with use Do not abrasive products to clean the heater Watch the pilot flame while it is in operation It should burn steadily if it flickers or is...

Страница 12: ...the heater off if you leave the area and never leave a heater on while sleeping or if you leave home k Always use specified or standard wire plug and socket always protect them from moisture or water...

Отзывы: