P. M. Lighting Professional CS Series Скачать руководство пользователя страница 3

         

  

 

Use the Easy Design Guide to help determine the best way to wire your fixtures to create optimal results in the 
illumination of your home. Follow these simple rules for best results: 

1.

 

It is recommended that you use 

2 MAIN SUPPLY CABLE

 runs from the transformer for best results and 

easiest installation, especially when you need to install fixtures on both sides of the transformer.    
 

2.

 

For short distances from the transformer (under 60 feet), only a single

 MAIN SUPPLY CABLE 

may be used to 

install this LED system for even easier installation. If the transformer is located on one end of the house, 
simply run a cable from the transformer to the various lights, leaving a little extra slack to make burying the 
cable easy.  
 

3.

 

DO NOT EXCEED the MAXIMUM WATTAGE

 listed for each length of MAIN SUPPLY CABLE used or the 

voltage at the fixtures will be lower than required causing the LED to flicker or not light at all. If any lights, 
especially  on the end of the 

MAIN SUPPLY CABLE, 

do not light or experiences flickering, make sure the 

transformer is on the HIGH setting (See #4 below) and check to make sure the quick connectors on each 
light fixture  are properly installed and are making a good connection.  
 

4.

 

SHORTER lengths for the MAIN SUPPLY CABLE lowers

 voltage drop on the line while 

LONGER lengths 

increases

 the voltage drop. Use the Line Length/Wattage Chart below to determine the maximum wattage 

load for various lengths of the MAIN SUPPLY CABLE.  
 

5.

 

The total wattage for the CS Pro Series systems range from just 30 watts for the CS6100-LED 6 light kit to 
50 watts for the largest CS12100-LED 12 light kit 

, providing ample room on the standard 100 watt 

transformer to add additional CS Professional Series LED fixtures to expand your system. The chart below 
will help determine the maximum amount of fixtures you can have on the system when you add up the total 
wattage from all fixtures on the line / system.    

 

 

   

Total Length of Main 

Supply Cable  

Maximum Wattage 

Available for Fixtures  

 CS Professional Series 

LED Fixtures  

Individual Fixture 

Wattage  

50 Feet 

90 watts 

CS936-LED Path Light 

3.0 watts 

60 Feet  

75 watts 

CS937-LED Bullet Light 

5.0 watts 

70 Feet 

60 watts 

CS938-LED Deck Light 

2.0 watts 

80 Feet 

55 watts 

CS933-LED Well Light 

6 watts 

90 Feet 

50 watts 

*Quantity and type of fixtures will vary by model of  

100 Feet 

45 watts 

   Kit purchased. See product label for more details. 

 

Содержание Professional CS Series

Страница 1: ......

Страница 2: ...n reach of the transformer power cord Attach and secure transformer to the wall a minimum of 12 inches above ground using screws and anchors if needed Mounting screws are provided for your convenience...

Страница 3: ...make sure the quick connectors on each light fixture are properly installed and are making a good connection 4 SHORTER lengths for the MAIN SUPPLY CABLE lowers voltage drop on the line while LONGER le...

Страница 4: ...ables from the transformer to split the fixtures into two 2 groups For best results follow these tips 1 Keep cables as short as possible 2 Leave enough slack to make burying cable easier 3 Make sure t...

Страница 5: ...rsons Keep away from combustibles Lamp gets hot very quickly Turn off or unplug luminaire and allow lamp to cool to change bulb Do not touch lamp with bare hands When using this fixture with high watt...

Страница 6: ...o persons Keep away from combustibles Lamp gets hot very quickly Turn off or unplug luminaire and allow lamp to cool to change bulb Do not touch lamp with bare hands When using this fixture with high...

Страница 7: ...ditional wire or cable please contact the manufacturer customer service or contact a qualified electrician Safety Warning LAMP IS HOT WHEN LUMINAIRE IS ON Hot lamp creates risk of fire and injury to p...

Страница 8: ......

Страница 9: ...he wiring compartment cover by pulling outward on the cove to swing it up to the open position The enclosures have a knockout on the bottom of the housing for the low voltage cable to enter through a...

Страница 10: ...CABLE RUN MUST BE CONNECTED TO 1 LEFT AND 2 RIGHT SEE DIAGRAM BELOW 3 ATTACH ONE SIDE OF THE MAIN CABLE RUN TO THE LEFT TERMINAL 1 BY INSERTING THE STRIPPED WIRE APPROX INTO THE BOTTOM OF THE TERMINA...

Страница 11: ...Wire Right Wire Strip Length Approx For a single home run cable twist the strands of copper wire together tightly for each side For more than one home run cable twist the strands of copper wire togeth...

Страница 12: ......

Отзывы: