Stopping the engine
1.
Switch off the electrical equipment and disconnect it.
2.
Let the engine operate for a few minutes.
3.
Switch the engine off by turning the engine’s “RUN” switch to “OFF”.
4.
Close the fuel cock.
Storage
When storing for longer periods, the fuel tank should be emptied of petrol.
Wipe the generator using a damp cloth. Never use a jet of water to clean the
generator.
Engine maintenance
•
Replace the oil every 25 operating hours.
•
Clean the air filter every week or more often in dusty operating conditions.
Troubleshooting
Problem
Cause
Solution
Engine does not
start
The fuel cock is closed. No fuel
in the tank.
Oil is not filled to the correct
level.
The engine switch is in the “OFF”
position. The choke is not set
correctly.
The spark plug is dirty.
The air filter is blocked.
Open the cock.
Fill the fuel tank. Fill the
oil to the correct level.
Set the switch to the
“ON” position. Set the
choke correctly.
Clean/replace the spark
plug.
Clean/replace the air filter.
Engine runs
unevenly
The air filter is blocked.
The spark plug is dirty.
The choke is set
incorrectly.
Dirty/old fuel.
Clean/replace the air
filter. Clean/replace the
spark plug. Set the
choke to the correct
position.
Drain old fuel and fill with
new fuel.
No electrical
power
Control fuse has tripped.
Switch off the electrical
equipment,
and reset the fuse.