SPECIFICATION / REPLACEMENT PARTS
Unit
FlyZap16
Voltage
230V ~ 50Hz
Dimensions(mm)
350 x 120 x 270
Coverage
40 Sq. Meters
Weight
2.5 Kg
Light Output
1
6W
Tubes
2 x I610
Starter
2 x I154
Unit
FlyZap 30
Voltage
230V ~ 50Hz
Dimensions(mm)
500 x 120 x 320
Coverage
80 Sq. Meters
Weight
3.5 Kg
Light Output
30W
Tubes
2 x I603
Starter
2 x I154
C
2009
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
R3 02/09
WEEE Compliance No. 01576542
TUBE REPLACEMENT
BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
To ensure the efficiency of
FlyZap
®
in catching flying insects, the UV tubes should be
replaced annually. After twelve months the phosphor coating that emits the
correct wavelength of UV light has burnt away and the UV output is diminished
substantially.
To replace the UV tubes…
1. Open the swing down front guard by unscrewing the two retaining clips.
2. Rotate the tube through 90°, freeing it from the tube holders.
3. Pull the tube away from the chassis.
4. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tube. Starters wear out and
should be replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
Tube Replacement
Starter Replacement