SPECIFICATION / REPLACEMENT PARTS
Unit
Flyzap 16
Voltage
230V ~ 50Hz
Dimensions(mm)
350 x 120 x 270
Coverage
40 Sq. Meters
Weight
2.5 Kg
Light Output
16W
Tubes
2 x I610
Starter
2 x I154
Guarantee
1
year
Unit
Flyzap 30
Voltage
230V ~ 50Hz
Dimensions(mm)
500 x 120 x 320
Coverage
80 Sq. Meters
Weight
3.5 Kg
Light Output
30W
Tubes
2 x I603
Starter
2 x I154
Guarantee
1
year
MAINTENANCE
BEFORE ANY FORM OF MAINTENANCE, ALWAYS
ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
CLEANING
It is recommended that you clean your
Flyzap
TM
once a month. First remove the catchment tray
and hygienically dispose of the caught flying
insects. Then thoroughly wipe down the tray and
exterior of your
Flyzap
TM
with a soft damp cloth,
removing any build up of dust or dirt.
TUBE REPLACEMENT
To ensure the optimum effectiveness of your
Flyzap
TM
,
the UV tubes should be replaced every 9 -
12 months.
To replace the tubes, unscrew the back guard
and swing down, giving access to the two used
tubes. Twist the used tube through an angle of 90°
as shown in the diagram until it can be pulled free
of the tube clips. Reverse the process to fit the
new tube.
STARTER REPLACEMENT
The starters should be replaced at the same 9 - 12
month interval as the tubes.
To replace the starters release the used starter by
turning anti-clockwise and pulling free. Insert the
new starter and turn clockwise until locked in
position.
Tube Replacement
1.
2.
Wall / Ceiling
Installation
Starter Replacement
1.
2.