background image

 

       SPECIFICATION / REPLACEMENT PARTS

Unit  

Flyzap 16 

Voltage  

230V   ~   50Hz

Dimensions(mm) 

350 x 120 x 270

Coverage 

40 Sq. Meters

Weight  

2.5 Kg

Light Output 

16W

Tubes

 

 

2 x I610 

Starter

 

 

2 x I154

Guarantee

 1 

year

Unit  

Flyzap 30

Voltage  

230V   ~   50Hz

Dimensions(mm) 

500 x 120 x 320 

Coverage 

80 Sq. Meters

Weight  

3.5 Kg 

Light Output 

30W 

Tubes

 

 

2 x I603 

Starter

 

 

2 x I154 

Guarantee

 1 

year

MAINTENANCE

BEFORE ANY FORM OF MAINTENANCE, ALWAYS 

ENSURE THAT THE UNIT IS DISCONNECTED FROM THE 

MAINS SUPPLY.

CLEANING 

It is recommended that you clean your 

Flyzap

TM

 

once a month.  First remove the catchment tray 

and hygienically dispose of the caught flying 

insects.  Then thoroughly wipe down the tray and 

exterior of your 

Flyzap

TM

 with a soft damp cloth, 

removing any build up of dust or dirt.

TUBE REPLACEMENT

 

To ensure the optimum effectiveness of your 

Flyzap

TM

,

 the UV tubes should be replaced every 9 - 

12 months. 

To replace the tubes, unscrew the back guard 
and swing down, giving access to the two used 
tubes.  Twist the used tube through an angle of 90° 
as shown in the diagram until it can be pulled free 
of the tube clips.  Reverse the process to fit the 

new tube.

STARTER REPLACEMENT

The starters should be replaced at the same 9 - 12 

month interval as the tubes.  

To replace the starters release the used starter by 

turning anti-clockwise and pulling free.  Insert the 

new starter and turn clockwise until locked in 

position.