P+L Systems Satalite 18 Скачать руководство пользователя страница 2

30W Tube Replacement

SPECIFICATION / REPLACEMENT PARTS

Unit  

Satalite 18 

Unit  

Satalite 30

Voltage  

230V   ~   50Hz 

Voltage  

230V   ~   50Hz

Dimensions(mm)  312 x 300 x 134  

Dimensions(mm)  312 x 540 x 170 

Coverage 

30 Sq. Meters 

Coverage 

60 Sq. Meters

Weight  

1.3 Kg 

 

Weight  

2.0 Kg 

Light Output 

18W  

Light Output 

30W 

Tube 

 

1 x TPX18  

Tubes 

 

2 x TPX15-18

Starter   

1 x I154   

Starters   

2 x I154 

Glueboards (x6) INL147 

(White)  Glueboards (x6)  INL161  (White)

GLUEBOARD REPLACEMENT

GLUEBOARD REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER 

ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

The glueboard should be replaced every month with a genuine glupac

®

 glueboard.  Use of 

non-approved glueboards may invalidate your guarantee.

To replace the glueboard…

 

1. Remove the used glupac

®

 glueboard by simply sliding it out of the top of

 

    the front reflector and either retain for insect evaluation or dispose of it hygienically.

 

2. Remove the protective release paper from the new glupac

®

 glueboard.

 

3. Slowly slide the new glueboard into position along the two runners with

 

    the adhesive side facing the tube(s).

Always ensure the selected genuine glupac

®

 glueboards are compatible with your unit, available 

from your pest control operator or P+L Systems Ltd.

TUBE REPLACEMENT

TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT 

THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

To ensure the efficiency of Satalite

TM

 in catching flying insects, the UV tube(s) should be replaced 

annually.  After twelve months the phosphor coating that emits the correct wavelength of UV light 

has burnt away and the UV output is diminished substantially. 

To replace the UV tube(s) first remove the front guard as shown in the diagrams on the previous 

page.  Then remove the tube(s) by...

Satalite

TM

 18 

1. Pull the tube gently from the tube holder until it un-clips. 

 

 

2. Gently rotate the tube until it becomes free from the tube support.

                             3. Dispose of the used UV tube in conjunction with local WEEE regulations.

Satalite

TM

 30 

1. Rotate the tube through 90 degrees. 

 

 

2. Gently pull the tube away from the unit.

 

 

3. Dispose of the used UV tubes in conjunction with local WEEE regulations.

STARTER REPLACEMENT

STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING 

THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.

The starter(s) provide(s) an extra spark to initially light the UV tube(s).  Starters wear out and should 

be replaced at the same intervals as the UV tube(s).

To replace the starter(s)…

 

1. Rotate the starter anti-clockwise.

 

2. Pull the starter free from the unit.

18W Tube Replacement

Glueboard Replacement

Starter Replacement

R4  04/14

C

2014

P+L Systems Ltd

Information provided on these instructions is modified and 

updated from time to time.  This is due to the constant 

redevelopment of our products.  As such, it is not intended that 

you should rely on it or that it should form part of any contract.  

Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ      UK

T  +44 (0)800 988 5359
F  +44 (0)1423 863 497
W  www.pandlsystems.com
E  [email protected]

                                                        WEEE Compliance No. WEE/GF0661QR 