background image

Tube Replacement

Starter Replacement

SPECIFICATION / REPLACEMENT PARTS

Unit  

FTP30

Voltage  

230V   ~   50Hz

Dimensions(mm) 

470 x 305 x 152 

Coverage 

80 Sq. Meters

Weight  

4 Kg 

Light Output 

30W 

Tubes

 

 

2 x I616 

Starter

   

2 x I154 

Glueboards (x6)

 INF196

Unit  

FTP40

Voltage  

230V   ~   50Hz

Dimensions(mm) 

610 x 305 x 152 

Coverage 

120 Sq. Meters

Weight  

5 Kg 

Light Output 

40W 

Tubes

 

 

2 x I618 

Starter

   

2 x I154 

Glueboards (x6)

 INF198

Unit  

FTP80

Voltage  

230V   ~   50Hz

Dimensions(mm) 

610 x 305 x 152 

Coverage 

240 Sq. Meters

Weight  

5 Kg 

Light Output 

80W 

Tubes

 

 

2 x I662 

Starter

   

2 x I154 

Glueboards (x6)

 INF198

GLUEBOARD REPLACEMENT

BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS 

DISCONNECTED FROM THE MAINS SUPPLY.

The glueboard should be replaced every month with a genuine glupac™ 

glueboard.  Use of non-approved glueboards may invalidate your guarantee.

To replace the glueboard…

 

1. Remove the used glupac™ glueboard by simply lifting it clear from the  

 

    unit and either retain for catch evaluation or dispose of it hygienically.

 

2. Remove the protective release paper from the new glupac™ glueboard.

 

3. Slowly slide the new glupac™ glueboard into position along the two  

 

    runners with the adhesive side facing the tubes.

Always ensure the selected genuine glupac™ glueboards are compatible with your 
unit, available from your PCO or P+L Systems Ltd.

TUBE REPLACEMENT

BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED 

FROM THE MAINS SUPPLY.

To ensure the efficiency of 

Flytrap Professional

TM

 in catching flying insects, the UV 

tubes should be replaced annually.  After twelve months the phosphor coating that 

emits the correct wavelength of UV light has burnt away and the UV output is 

diminished substantially. 

To replace the UV tubes…

 

1. Rotate the tube through 90°, freeing it from the tube holders.

 

2. Pull the tube away from the chassis.

 

3. Dispose of the used UV tube in conjunction with local WEEE regulations.

STARTER REPLACEMENT

BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED 

FROM THE MAINS SUPPLY.

The starters provide an extra spark to initially light the UV tube.  Starters wear out and 

should be replaced at the same intervals as the UV tubes.

To replace the starters…

 

1. Rotate the starter anti-clockwise.

 

2. Pull the starter free from the unit.

Glueboard Replacement

WEEE Compliance No. 01576542

C

2009

P+L Systems Ltd

Information provided on these instructions is modified and 

updated from time to time.  This is due to the constant 

redevelopment of our products.  As such, it is not intended that 

you should rely on it or that it should form part of any contract.  

P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB      UK

T  +44 (0)800 988 5359
F  +44 (0)1423 863 497
W  www.pandlsystems.com
E  [email protected]

R3 02/09

Отзывы: