Tie the cable to the holes in the cover 

of the electric pump;

 

Lower the electric pump into the water 

and fi x the cable over the well, well, etc.

The pump must be located at least 60 cm 

from the bottom and 50 cm from the surface 

of the water.

Do not allow the entry of foreign bodies, sharp 

objects, etc. into the hole in the cover at the 

bottom of the electric pump to avoid damage 

to the rubber diaphragm.

Lower the electric pump, holding the cable 

and pipeline, watch out for free suspension 

of the power cord. When lowering the electric 

pump, protect the cord from possible damage. 

After lowering the electric pump into the well, 

fix the cable and pipeline on the surface in 

such a way that the weight of the pipeline and 

the water in it is not transferred to the power 

cord.

ATTENTION! 

The condensing box and the 

socket must be placed under a shed or in-

doors, protected from possible exposure to 

splashing water and atmospheric precipita-

tion.

To eliminate the possibility of clogging of the 

pumping part, it is recommended to install a 

check valve at the pump outlet.

Operating procedure

Before connecting the electric pump to the 

network, make sure it is completely immersed.

Connect the electric pump to the mains with a 

plug.

Attention! 

Operate the electric pump only in 

a developed and cleaned well. If contaminat-

ed water appears, the electric pump should 

be turned off and the position of the pump 

relative to the bottom of the reservoir or well 

should be checked again.

Remember that pumping water with a high 

content of mechanical impurities leads to a re-

duction in the service life of the electric pump 

and voids the right to warranty repair.

The performance of the electric pump de-

pends on the depth of the water, the length, 

diameter and type of the pipeline used, etc. 

To prevent pumping out of water from the 

well, the well, match the productivity of the 

latter with the volumetric fl ow of the pump by 

closing the valve installed at the outlet of the 

pipeline from the well, well. In this case, the 

volumetric fl ow should not be less than 400 l 

/ h. A further decrease in the volumetric fl ow 

and complete shut-off  of the valve can lead to 

overheating and failure of the electric pump.

In order to avoid overheating and damage 

to excess supply cable, during operation of 

the electric pump, do not leave it in a tightly 

wound coil, which impedes the access of air 

for cooling.

In the event that the operating pump stops 

due to the activation of the thermal relay, 

turn on the electric pump after the relay has 

cooled down and eliminate the causes of op-

eration by pressing the relay activation button 

on the capacitor box (depending on the pump 

model).

Lowering the voltage in the network when the 

electric pump is running, leads to a decrease 

in the head developed by the pump, produc-

tivity and to an increase in the current con-

sumption.

When the voltage in the network drops below 

200V, it is recommended to use a voltage sta-

bilizer of the appropriate power, or bring the 

voltage back to normal in another way.

Storage and maintenance

Be sure to flush the pump with clean water 

after each use.

Storage

In case of prolonged inactivity of the pump, as 

well as in winter, storage must be carried out 

in a dry, heated room. First, it is necessary to 

drain the remaining water from it and pipes, 

rinse with clean water and dry.

The pump does not require preservation. It 

should be stored at temperatures b 1 

° C and + 35 ° C, away from heating devices 

and avoiding direct sunlight.

Service

Have your power tool repaired by qualifi ed 

personnel only and using original replace-

ment parts to ensure the safety of your 

power tool.

For a list of authorized service 

centers, see the official P.I.T. link https://pit-

tools.ru/servises/

Description of product date

The date of manufacture of the product is 

encrypted in the serial number printed on the 

body of the instrument. The fi rst 2 digits indi-

cate the year of manufacture, the next 2 digits 

are the month and the next 2 digits are the 

day.

Recycling

When disposing of a damaged pump, take all 

measures to avoid harm to the environment. 

Do not attempt to dispose of the pump your-

self. It is highly recommended that you con-

tact the dedicated.

Maintenance and cleaning

Содержание PSW750-T1

Страница 1: ...OPERATION MANUAL...

Страница 2: ...Screw Pump 1 2 3 1 4...

Страница 3: ...the insulation When connecting the product to the mains power supply use only ground ed electrical outlets to avoid electric shock Unsuitable power plugs can be dan gerous Outdoors use only approved...

Страница 4: ...instructions Intended use The pump is designed for pumping clean water from wells wells reservoirs and reser voirs for automatic water supply systems at home for irrigation of gardens and vegetable g...

Страница 5: ...his case the volumetric ow should not be less than 400 l h A further decrease in the volumetric ow and complete shut o of the valve can lead to overheating and failure of the electric pump In order to...

Страница 6: ...g cases in the absence of a Warranty Certi cate and a Warranty Card or their incorrect execution with failure of both a rotor and a stator of the electric engine charring or melting of primary winding...

Страница 7: ...here are signs of excessive heat sparking or noise in the gearbox To determine the cause of the malfunction the buyer should contact the warranty service center Malfunctions caused by late replacement...

Страница 8: ...7 30 1 35 16...

Страница 9: ...8 1 2 3 4 M PSW750 T1 220 50 900 2 0 3 130 12 5 1 1 1 P I T...

Страница 10: ...9 1 60 50 400 200...

Страница 11: ...10 1 35 P I T https pittools ru servises 2 2 2 1 2 OnePower 12 I 3 4...

Страница 12: ...11 3 2 2 5...

Страница 13: ...Warranty Card the boxes shall be lled out by a seller and to a x the seal of the trade organization in the Guarantee Certi cate and the Warranty Card Warranty By this Warranty Certi cate P I T compan...

Страница 14: ...13 I ___________ _____ ____________________ I I www pittools ru I I I 12 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ________________________ ________________...

Страница 15: ...____________________________ Serial Number___________ Sale Date ____________20__ Place of Seal Filled out by a Seller WARRANTY REPAIR CARD Date of Acceptance for Repair _______20___ Application for Re...

Страница 16: ...0__ ___20__ ________________________________ ___________ ________20__ Place of Seal O O _______20___ ___________________ _____________________________ ________________________ _____________________ __...

Страница 17: ......

Отзывы: