P.I.T. POG750-P Скачать руководство пользователя страница 4

Self-priming Pump

3

pumping station during its operation. Make 

sure that children do not played with the 

device.

Safety instructions

When working with a pumping station

 

► Any use of the pumping station in violation 

of the rules for its operation is considered 

misuse.

 

► For  damage  resulting  from  the  use  of 

misuse,  the  answer  is  only  the  user  is 

responsible.

 

► The pumping station is not intended for 

professional or industrial use. Long-term 

nondiscontinuous use.

 

► Unauthorized introduction of changes in 

the design of the pumping station, as well 

as the use of parts that did not pass their 

tests and not approved for manufacturer’s 

application.

 

► Do  not  pump  explosive  dangerous, 

flammable,  aggressive  or  substances 

hazardous  to  health,  as  well  as  water 

containing mechanical mixtures in the form 

of sand, stones, etc.

 

► The pumping station is not intended for 

pumping  chlorine-containing  water  in 

fl oating swimming pools.

 

► Not recommended for pumping drinking 

water.

 

► When starting up the pumping station for 

the first time, ensure that it is completely 

fi lled with water. It is not allowed to operate 

the pumping station without water.

 

► Do not allow air to enter suction line.

 

► To avoid freezing, you must completely 

drain the water from the pumping station, 

as well as the same suction and pressure 

mains lei.

Service

Repairing your power tool commission only 

qualifi ed personnel and only with the use the 

use of original spare parts.

List  of  authorized  service  centers  can  be 

viewed on the offi  cial website P.I.T. by the link: 

https://pittools.ru/servises/

Product description and specifi-

cations

Read all the safety and general in-

structions. 

Failure to observe the safety and gen-

eral instructions may result in electric shock, 

fi re and/or serious injury.

Please observe the illustrations at the begin-

ning of this operating manual.

Intended use

The pumping station is designed to provide 

constant pressure of clean water when ar-

ranging water supply systems, watering lawns 

and irrigating garden plots, as well as for 

pumping water from tanks or reservoirs.

The design of the pumping station (full auto-

mation, rare activation, supply of water under 

pressure) allows the pumping station to be 

used as an economical, maintenance-free 

source  of  constant  water  pressure.  Large 

intake depth, water supply height and high 

performance  ensure  the  versatility  of  this 

pumping station for any country house.

Pump device

The general view of the tool is presented on 

the page with illustrations.

1.Pump

2.Hydraulic accumulator

3.Connecting hose

4.Pressure switch

5.Manometer

6.Pneumatic valve

Technical data

Model

POG750-P

Rated voltage

220 V~/50 Hz

Rated power

750 W

Performance

2.8 m³/h

lifting height

50 m

Accumulator volume

24 L

Suction depth

8 m

The weight

17 Kg

Contents of delivery

Self-priming pump                                

1 pc.

User manual                                             1 pc.

Note

Text and numbers may contain technical er-

rors and typographical errors.

As the product is constantly being improved, 

P.I.T. reserves the right to make changes 

to the specifications and equipment of the 

product specified here without prior notice.

Preparation for work 

The station consists of a pump (1), a hydrau-

lic accumulator (2), a connecting hose (3) and 

an automation unit, consisting of a pressure 

switch (4) and a pressure gauge (5). The ac-

cumulator has a food-grade rubber membrane 

in the inner cavity and a pneumatic valve (6) 

for adjusting the air pressure.

The pump has inlet (7) and outlet (8) open-

ings, as well as fi ller (9) and drain (10) open-

ings.  For  JS  series  pumps,  water  is  filled 

through the pump outlet (8).

Содержание POG750-P

Страница 1: ......

Страница 2: ...Self priming Pump 1 1 4 5 6 2 3 7 9 10 8...

Страница 3: ...ed for use and appropriately marked electrical tricic extension cords with sufficient cross section of the wire Do not use the mains power cable for transportation or xation device When disconnecting...

Страница 4: ...nd gen eral instructions may result in electric shock re and or serious injury Please observe the illustrations at the begin ning of this operating manual Intended use The pumping station is designed...

Страница 5: ...ource of at least one degree to the horizon reverse angles on the suction line are not al lowed Electrical connection ATTENTION The electrical connection should only be carried out after all hydrau li...

Страница 6: ...he product seri al number from left to right Year of production the third and fourth digits indicate the month of production the fth and sixth digits indicate the production day TERMS OF WARRANTY SERV...

Страница 7: ...anthers piston and sealing rings during the warranty period is a paid service The service life of the product is 3 years Shelf life is 2 years It is not recommended for oper ation after 2 years of st...

Страница 8: ...7 30 1 35 10 2 16...

Страница 9: ...8 P I T https pittools ru servises 1 2 3 4 5 6 M POG750 P 220 50 750 2 8 3 45...

Страница 10: ...9 M POG750 P 24 L 8 17 1 1 P I T 1 2 3 4 5 6 7 8 9 10 JS 8 0 15 1 5 0 3 3 1 1 7 8 1 10 30...

Страница 11: ...10 9 6 0 15 1 5 P I T https pittools ru servises 0 35 80...

Страница 12: ...11 2 2 2 1 2 OnePower 12 I 3 4...

Страница 13: ...12 3 2 2 5...

Страница 14: ...the Warranty Card the boxes shall be lled out by a seller and to a x the seal of the trade organization in the Guarantee Certi cate and the Warranty Card Warranty By this Warranty Certi cate P I T com...

Страница 15: ...14 I ___________ _____ ____________________ I I www pittools ru I I I 12 _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ________________________ ________________...

Страница 16: ..._______________________________ Serial Number___________ Sale Date ____________20__ Place of Seal Filled out by a Seller WARRANTY REPAIR CARD Date of Acceptance for Repair _______20___ Application for...

Страница 17: ...0__ ___20__ ________________________________ ___________ ________20__ Place of Seal O O _______20___ ___________________ _____________________________ ________________________ _____________________ __...

Страница 18: ......

Отзывы: