background image

1

GENERAL SAFETY PRECAUTIONS

1.Most of the units and parts are made of light alloys and plastic, designed for long-term use, but 
not protected from shock overloads; transportation must comply with the transport regulations!
Take care in handling and transportation to avoid falls and bumps.
2.Never leave flammable substances near the compressor. Never direct compressed air to a face.
3.Keep children and animals away from the compressor or other equipment connected to it. The 
compressor head and air ducts are heated during operation.
4.Protect compressor from moisture penetration.
5.Do not use compressor at construction sites.
6.Do not operate compressor at maximum modes for more than 5 hours (total time).
7.Do not operate compressors in explosive environments (gasoline vapors, gas, etc.) and at low 
temperatures. Remember! The pressure relay does not turn off the compressor in an explosive 
environment.
8.The air used for compressor cooling when carrying out paint and varnish works, purging and air 
cleaning shall be clear and free from particles, pigments of coloring substances, and solvents. Do 
not perform painting in an unventilated area or near an open flame. Protect nose and mouth with a 
mask;
9.The compressor shall be operated by specially trained professionals only.
10.Use additional oil separators, moisture traps to provide high quality of compressed air.
11.Do not transport the compressor without container and with the pressurized receiver. Before 
servicing the compressor, make sure that the pressure has been released from the receiver and 
the power is off. After any maintenance operation, make sure all components are properly installed 
and fixed.
12.The compressor shall be operated in well-ventilated areas only.
13.Never disconnect power by pulling the plug out of the socket or otherwise while the compressor 
is running, it may case the electric motor lug when restarting. The compressor shall be turned 
on/off only by pressing/pulling the red switch located on the pressure relay.
14.Never unscrew connections when the receiver is under pressure.
15.W
16.Unplug the compressor when not in use. This is especially important in the evening when power 
surges are possible in the industrial power network, which can lead to electric motor overload and 
failure.

It is prohibited:

1.To operate the compressor with defective or disabled protection;
2.To make any changes to the electrical or pneumatic circuits of the compressor or their adjust-
ment. In particular, change the value of compressed air maximum pressure and a safety valve 
settings;
3.To touch highly heated components (cylinder head and cylinder block, cooler, parts of the 
discharge air duct, cooling fins of the electric motor) when operating the compressor;
4.To perform machining or welding of the receiver. In case of defects or corrosion, it is necessary 
to completely replace it, as it falls under special safety standards;
5.To touch the compressor with wet hands or work in wet shoes;
6.To direct compressed air to yourself or nearby people;
7.To allow children and animals into the work area;
8.To perform painting work in an unventilated area or near an open flame;
9.To store kerosene, gasoline and other flammable liquids at the compressor installation site;
10.To leave a powered compressor unattended;
11.To perform repairs when a compressor is powered and receiver is pressurized.

Air compressor

Содержание PAC016001-2.5/100

Страница 1: ...PAC016001 2 5 100 PAC016002 3 3 100 AIR COMPRESSOR PROGRESSIVE INNOVATIONAL TECHNOLOGY...

Страница 2: ...enance operation make sure all components are properly installed and fixed 12 The compressor shall be operated in well ventilated areas only 13 Never disconnect power by pulling the plug out of the so...

Страница 3: ...e operation time PRINCIPLE OF OPERATION The principle of operation of this type of air compressors is not complicated It looks as follows The entire working cycle consists of only two piston movements...

Страница 4: ...gun applying anti corrosion compounds purging for polishing and grinding pneumatic tools Features electric motor with thermal protection gearbox for pressure control convenient handle and large wheel...

Страница 5: ...e con densate from the receiver It is used to discharge air into the atmosphere Ii is installed in the discharge pipe of the compressor In the closed position the valve is held by a spring It is used...

Страница 6: ...e compressor on a horizontal flat platfo rm taking into account its ma ss and overall dimensions 1 Carefully read and follow the instruction manual 2 Open the package check the complete ness and make...

Страница 7: ...nd the gasket or replace it Causes 1 Insufficient oil level in the compressor crankcase 2 Prolonged compressor operation at maxi mum pressure and air consumption ther mal protection is triggered 3 Low...

Страница 8: ...il Change Change oil after the first 100 hours of operation and then every 300 hours It is necessary to periodically check the oil level upon completion of work and drain the condensate that has accu...

Страница 9: ...e power cord and in case of damages caused by aggressive agents and high and low temperatures ingress of foreign objects in the ventilation grids of the electric machine as well as in case of damage r...

Страница 10: ...be filled out by a seller and to affix the seal of the trade organization in the Guarantee Certificate and the Warranty Card Warranty By this Warranty Certificate P I T guarantees that the products i...

Страница 11: ...10 P I T WARRANTY CARD Air compressor...

Страница 12: ...11 1 2 3 4 5 6 5 7 8 9 10 11 12 13 14 15 0 35 16 1 2 3 4 5 6 7 8 9 10 11...

Страница 13: ...12 PAC016001 2 5 100 PAC016002 3 3 100 2 5 100 PAC016001 2 5 100 AC Air compressor 016001 2 5 100 2500 3300 100 100 330 370 P I T...

Страница 14: ...13 PAC016001 2 5 100 PAC016002 3 3 100...

Страница 15: ...14 1 2 3 5 6 7 8 9 10 11 4...

Страница 16: ...15...

Страница 17: ...16 1 2 1 2 1 1 1 2 3 1 2 3 1 1 1 1...

Страница 18: ...17 100 1 2 100 300...

Страница 19: ...18 1 2 12 P I T 3 4 5 5...

Страница 20: ...19 P I T P I T P I T P I T P I T P I T P I T 12 ______________________________ __ ______________ ____________________...

Страница 21: ...ate of Acceptance for Repair 20 Application for Repair Customer Phone Address Cause of Application Date of Receipt from Repair 20 The Tool is checked in my presence The Order shall be performed in a S...

Страница 22: ...21 P I T...

Страница 23: ...22...

Страница 24: ...23 Air compressor PAC016001 2 5 100...

Страница 25: ...24 Air compressor PAC016002 3 3 100...

Страница 26: ...pit tools com Xinjiang Longbo Industrial Co Ltd Rm 602 6th Floor No 531 Weixing Road Economic And Technological Development Zone Urumqi Xinjiang China 602 6 531 614058 36 info pittools ru Made in Chi...

Отзывы: