background image

 
 
 
 

Ultimo aggiornamento: 30/09/21 

 

 

2

 

 

 

INSTRUCTIONS  

 

SELECTION  

This  product  is  to  be  used  with  clean  water,  even  slightly  mixed  with  normal  detergents.  For  use  with  different  or  corrosive  liquids, 
please contact the PA Technical department. Appropriate filtration should be installed when using unpure liquids. Please make sure 
that the valve is in line with the working data of the machine where it is to be installed (permissible pressure, maximum flow and rated 
temperature of the system). In any case, the pressure of the machine must not exceed the permissible pressure marked on the valve. 
 
 

OPERATION 

The valve limits the maximum pressure in the circuit. In case of overpressure, a bypass port is opened through which the excess   wa-
ter is discharged. During normal operation of the system, a spring-pulled shutter closes the bypass. The calibration pressure is       ad-
justed by varying the spring thrust through the appropriate adjusting screw. 

 
 
INSTALLATION 

In  a  hot  water  machine,  the  valve  should  be  mounted  upstream  of  the  boiler.  In  any  case,  even  in  cold  water  applications,  if  an        
accidental overheating of the water is foreseen, the installation of thermal protection devices is advisable in order to keep the water 
temperature below the maximum allowed temperature (MAX TEMPERATURE). 

 

It is advisable to return the discharge flow to a tank. It is advisable for the tank to be equipped with baffles in order to reduce any      tur-
bulence and air bubbles generated by the bypass flow, which could be damaging to the pump. When discharging in the atmosphere, 
ensure to direct the valve properly in order to avoid serious injuries.  
 