INSTALLATION OF THE APPLIANCE
10/15
If this applıance located near to any wall, separation, kitchen
furniture, decorative coating etc. the distance in between
should be min.20 cm. and if those are coated with fireproof heat insulating
material, the distance should be min. 5 cm. It is strongly recommended that fire
safety protection instructions are observed.
All of the items mentioned below in connection with the
installation of the applıance should be carried out by
authorized service personnel.
☞
Workbench on which the applıance stands should be adjustable and
the applıance should be ensured to operate in a leveled position.
☞
Power supply connection of the applıance should be checked by an
eligible electrician, and it should be connected to a fuse at a maximum
height of 170 cm.
☞
Power supply connection should be made using a 30 mA current
leakage fuse as
a protection against current leakage danger.
☞
Power installation to be used should be grounded by connecting it to a
grounding bar at the nearest panel.