5

 

Order Numbers 

Table 10 shows the order numbers for Pollux CoaXPress cameras. 

 

Part Number 

Description 

PX12M180MCP 

Camera, 12MP, monochrome, F-mount, CoaXPress 

PX25M80MCP 

Camera, 25MP, monochrome, F-mount, CoaXPress 

PX50M30MCP 

Camera, 50MP, monochrome, F-mount, CoaXPress 

 

Table 10.

 

Pollux CXP order numbers 

Содержание CoaxPress pollux PX50M30MCP

Страница 1: ......

Страница 2: ... Co Ltd will at its discretion either repair or replace the product at no cost In the case where a new device is to be provided but the product has been discontinued a product with similar or better performance capabilities and features will be provided This warranty shall not apply to any damage defect or failure caused by improper use or inadequate maintenance of the product CE Compliance This E...

Страница 3: ...chnology technology advancements and increasing productivity is crucial element for success Our company is currently researching new technology through internal employee education And this is just a part of our efforts in providing the best suited products and service to our customers We pursue to provide and share our experience and technology to the customers so they can successfully use our pro...

Страница 4: ...Trigger Input Design 11 3 3 LED Status Indicator 12 3 4 Installation 12 4 CameraFunctions 15 4 1 CoaXPress Output Format 15 4 2 Frame Rate and Exposure 16 4 3 Camera Mode 17 4 3 1 Free running 17 4 3 2 External Trigger Timed 18 4 3 3 External Trigger Width 19 4 4 Image Region of Interest 20 4 5 Offset and Gain 22 4 5 1 Black Level Offset 22 4 5 2 Analog Gain 22 4 5 3 Digital Gain 22 4 6 User Set 2...

Страница 5: ...CMV50000 Table 1 Covered Pollux CXP models 1 1 Key Features CXP6 4 in single connection out configurations Max Frame Rate 30 fps 12 bit Pipelined global shutter with Correlated Double Sampling CDS High sensitivity with low noise Programmable and triggered exposure control Region of interest ROI Vertical Y axis only Up to 4 ROIs User programmable Look up Table LUT for Defective pixel corrections Fi...

Страница 6: ...Pitch 4 6 x 4 6 μm2 Full Well Charge 14500 e Conversion Gain 0 27 DN e Responsivity 0 16 DN ph at 510nm Temporal Noise 8 8 e Dynamic Range 64 dB Dark Current 0 24 e s 20 Shutter Efficiency 1 18000 at 520nm f 8 FPN 0 20 rms of full swing DSNU 24 5 e PRNU 1 0 RMS Frame Rate 30 0 fps Full Frame Output Interface 22 LVDS 830 Mbps Power Consumption 3 0 W Cover Glass D263T eco Package 141 pins cPGA Table...

Страница 7: ...ge 7 of 24 Manual 1 5 OZRAY Pollux Series 50M CXP 2 Mechanical Camera housings are made with high precision from machined aluminum Mechanical drawings are shown below Figure 1 Figure 1 Mechanical drawings ...

Страница 8: ...low Table 3 Specification Description Size 80 mm x 80 mm x 43 3 mm Weight 400 g no lens Mounting Holes Sides 8x M4x0 7 Front 4x M4x0 7 Power Connector 12 pin threaded Hirose Mating connector part HR10A 10TPA 12S 73 Interface 4 x BNC CoaXPress Standard Table 3 Mechanical specifications 2 2 Lens Adapters Figure 2 F mount lens adapter ...

Страница 9: ...n in Table 4 Connector type HR10A 10P 12 male Power connection Power connected to Pin 2 and Ground to Pin 1 Figure 3 Power connector Pin Description Pin Description 1 GND 7 External Trigger_OUT 2 DC Input 12V 24V 8 External Trigger_OUT GND 3 RXD RS232 9 External Trigger_IN0 4 TXD RS232 10 External Trigger_IN0 GND 5 External Trigger_IN1 11 NC 6 External Trigger_IN1 GND 12 NC Table 4 Power connector...

Страница 10: ...he camera can optionally be powered over the coax cable PoCXP from a compliant frame grabber on the CH1 and CH2 connectors It is recommended to remove the power adapter from the camera power connector when using the camera in a PoCXP configuration 3 1 CXP Connector The CoaXPress protocol includes an automatic link detection mechanism Plug and Play to correctly detect the camera to the CXP Frame Gr...

Страница 11: ...in 5 7 and 9 The inputs and output are connected to Opto islolated I Os in the camera with an input output voltage range of 2 5 V to 5 0 V There is a 510 Ω series resistor in the input path a 680 Ω series resistor in the output path The circuit diagram for the trigger inputs is shown in Figure 4 Figure 4 Trigger inputs and Strobe output circuit diagram ...

Страница 12: ...Procedures below also assume that you may attempt to configure a link between a camera and CXP Frame Grabber by using four coax cables For more detailed information refer to your CXP Frame Grabber User Manual To connect the camera to your computer follow the steps below 1 Make sure that the power supply is not connected to the camera and your computer is turned off Go on to step 2 if you are using...

Страница 13: ...the camera and the other ends of the coax cables into the CH3 and CH4 of the CXP Frame Grabber respectively b You must connect CH2 connector before plug CH1 to power the camera via PoCXP 4 Verify all the cable connections are secure Precautions for using Power over CoaXPress PoCXP To power a camera via PoCXP Frame Grabber you must connect CH1 after plug CH2 of the camera to their respective connec...

Страница 14: ...Page 14 of 24 Manual 1 5 OZRAY Pollux Series 50M CXP Figure 6 Installation using PoCXP ...

Страница 15: ...width as shown in table 7 CXP Connection Output Bandwidth Max Frame Rate CXP 6 4 25 Gbps 30 fps Table 7 Frame Rate The output pixel depth is 8 bit and 12 bit To be easy to use and convenience the camera always powers up in a CXP 6 with 4 connections mode while supporting default frame size period and exposure settings Thus user no needs to change CXP Connection command for the max frame rate 30 fp...

Страница 16: ...s Frame Time GLOB Time Read Out Time Our product automatically calculates maximum exposure according to the frame rate For example in case of 30 frame rate frame time is 33 333 μs and the exposure time is 33 183 μs The GLOB time depends on the output format and the LVDS clock period The readout time of a frame is equal to the number of lines in the output image The camera re calculates the allowab...

Страница 17: ...Time Command The sensor autonomously integrates during this predefined time after which the GLOB starts and the image array is readout sequentially A falling edge on the synchronization pin does not have any impact on the readout or integration and subsequent frames are started again for each rising edge Figure 7 shows the relation between the internal trigger signal and the exposure readout timin...

Страница 18: ... rising edge Figure 8 shows the relation between the external trigger signal and the exposure and readout timing If a rising edge is applied on the external trigger before the exposure time and GLOB of the previous frame is complete it is ignored by the sensor Figure 8 External trigger timing Timed Exposure starts when the high active edge of the input trigger is seen Also It is possible to use lo...

Страница 19: ...d level controlled exposure timing There is a GLOB period after the sensor is triggered to stop integration before the readout starts When the sensor enters this GLOB period there is a portion of time where the photodiodes are still being exposed to light before the charge is transferred to the storage elements For programmable exposure modes this time is included in the exposure time value The mi...

Страница 20: ...I is referenced to the top left corner origin 0 0 of the sensor array It also supports Multiple ROIs by 4 regions at Y axis Table 8 shows some sample ROI Vertical for the reference On the Pollux50MCP camera the Width parameters must be set to a multiple of 10 Otherwise the Height parameters can be set any positive integer value Height resolution Min Exposure Max Exposure Max Frame Rate 16 min 150 ...

Страница 21: ...21 of 24 Manual 1 5 OZRAY Pollux Series 50M CXP Figure 10 ROI Example ROI4 Offset Y ROI3 Offset Y ROI1 Offset Y ROI4 Height 7920 6004 ROI3 Height ROI2 Height ROI1 Height ROI Width ROI2 Offset Y ROI Offset X ...

Страница 22: ...ommand Valid range is 0 to 2 and the corresponding gain values are shown in Table 9 The analog gain is applied by a Programmable Gain Amplifier PGA in every column before the analog to digital conversion Analog Gain Register Gain 0 x1 00 Gain 0 dB 1 x2 00 Gain 3 0 dB 2 x4 00 Gain 6 0 dB Table 9 Analog gain settings 4 5 3 Digital Gain A digital gain can be applied using the Digital Gain register Th...

Страница 23: ...le 10 shows the order numbers for Pollux CoaXPress cameras Part Number Description PX12M180MCP Camera 12MP monochrome F mount CoaXPress PX25M80MCP Camera 25MP monochrome F mount CoaXPress PX50M30MCP Camera 50MP monochrome F mount CoaXPress Table 10 Pollux CXP order numbers ...

Страница 24: ...ification 1 0 05 15 17 Initial Release 1 1 06 22 17 Change Power Connector 1 2 09 06 17 Revise errors 1 3 03 15 18 Add ROI Descriptions 1 4 05 16 18 Modify Model Name 1 5 09 04 18 Remove Black Level Offset 2 command 7 Firmware Revision History Revision Date Modification 0 1 05 15 17 Initial Release ...

Отзывы: