4. Secure red wire into RLY 1 terminal, and black wire into +COM
terminal on Clack® control board.
5. Replace control valve front cover.
6. Plug the supplied wall transformer into a wall outlet. Plug the
male DC plug into the female DC jack located at the back of the
OzotechEOG.
7. Program ozone start and end schedule using control valve PCB.
4.2 Installation Continued
6.
a. Enter cycle programming mode
b. Set backwash to 14 minutes
c. Set draw time to 40 minutes
d. Turn off fill
e. Turn off rinse
f. Set relay to “on”
g. Set the relay on time to 15 minutes (one minute longer
than backwash)
h. Set the relay duration for 38 minutes (2 minutes less than
draw time)
i. Return to service
j. Press regeneration button to lock in timing
Содержание EOG
Страница 1: ...OzotechEOG Enhanced Oxidation Generator Installation and Service Manual M43 31506 ...
Страница 18: ...10 0 Illustrations Figure 1 OzotechEOG internal layout 16 ...
Страница 19: ...Maintenance Notes ...
Страница 20: ...Ozotech Inc 1015 South Main Street Yreka CA 96097 Ph 530 842 4189 ozotech com ...