background image

USER MANUAL EN 

 

READ THE INSTRUCTIONS CAREFULLY BEFORE USING THE OZONE 
GENERATOR

 

This ozone generator produces ozone gas. Ozone gas is toxic and hazardous to human and 

animal health in concentrations that exceed the OSHA (Occupational Safety and Health 

Administration) set exposure limits. 

During ozone treatment, the ozone concentration may under certain conditions, quickly 

exceed these set limits. Read section 1 to section 8 on the following pages to perform a 

safe ozone treatment. 

 

Safety regulations 

Check the product before use. The ozone generator must not be used if the 
appliance, the power cable, or the insulation seems damaged. If in doubt, contact 
the manufacturer. The generator contains electrical components and must 
therefore always be placed dry, never to be exposed to excess humidity, water 
splashes or running water. For all types of service or maintenance, the generator 
must always be disconnected from power. Ozone gas is toxic, so be aware of 
recommended room sizes. 

 

Recommended room sizes 

Ozone has a characteristic chlorine-like odor. The gas is toxic and will, in high 
concentrations, irritate the eyes and respiratory tract. The limit value for ozone 
gas is set at 0.1PPM for exposure up to 8 hours per day, or 0.3PPM for a 
maximum of 15 minutes. If the generator is used in a room that has a volume of 
less than 40 m3 and poor ventilation, the ozone concentration may exceed the 
mentioned limit values. Then it is important to make sure that the room is well 
ventilated before it can be reoccupied. If people or animals are in a room at the 
same time as it is ozonated, an ozone sensor must be installed which 
automatically switches off the power to the ozone generator if the ozone 
concentration in the room gets too high (above 0.1PPM). 

 

Odor removal 

 Approach 

The generator is placed on a stable surface or hung on a wall (fig. 3) in a dry place, 
preferably about 1.5 meters above the floor. Check that air supply to the 
generator and exhaust from the generator remains uncovered / open. Close all 
windows and valves. Empty the room of people, animals, and live plants. 
 
Page 3 

Connect the generator to power and start the generator with the red main switch 
(fig. 1). You will hear the fan start and a faint hum from the ceramic item. A green 
LED will indicate that the generator is producing high voltage (Fig. 1). You can also 
see through the exhaust grille that the ceramic element gives off a faint blue 
glare. The odor remediation effect is a function depending on time. The generator 
can run continuously for a week without any problem. For longer operation, we 
recommend that you use a simple timer and run the generator at shorter 
intervals. This will also reduce future need for maintenance. 
 

Service and maintenance 

Service-Kit

 can be ordered through your dealer or manufacturer. 

 

Make sure that the generator is not connected to power before starting work.  

Filter:

 The thin particle filter in front of the fan should be cleaned regularly. The 

filter cover is only clamped and can be loosened gently with your nails or a small 
screwdriver. Vacuum and / or wash it in mild soap and dry well before putting it 
back (fig. 4). 

Ceramic element 

This is a consumable part. Estimated service life 

3500 hours, depending on air 

quality / humidity. As long as it emits a blue glare, it produces ozone gas. For best 
effect, we recommend regular cleaning.  

Cleaning:

 Wipe the item with a q-tip or fine cloth dampened with window cleaner 

or rubbing alcohol (Fig. 5). Wipe with a dry cloth afterwards. The appliance must 
be completely dry before it can be restarted. 

Replacing the ceramic element:

 Loosen the 4 screws that hold the element. 

Loosen the quick connectors of the 2 red wires (fig. 6). Release the red wire from 
the green LED that is attached with 2 cable strips to one of the element's red 
wires. Fit the new element, remember the 4 spacer sleeves under the element 
when you fasten the 4 screws carefully. Connect the 2 quick connectors - then 
fasten one wire from the green LED lamp carefully along one of the element's red 
wires with 2 new cable strips. 

Other components

: All other service must be performed by the manufacturer. 

 

 