1. Turn the HVAC UV 560 off. Disconnect the power 
cord. Remove the UV tube retaining nut marked in the 
picture. 
 

 

 

2. Remove the rube by carefully sliding it out. 

 

3. In a normal situation the tube will just need to have the dust removed. This can be done using a dusting cloth such 
as a Swiffer® duster or Swiffer® cloth. 
If the tube has collected more than just dust you may clean it with mild soap and water. Be very careful not to damage 
the wires that run from one ceramic end cap to the other. 

4. If the tube was cleaned with mild soap and water make sure to rinse the soap off and make sure the tube is 100% 
dry before operating. Drying can be done by allowing the tube to sit in a warm place overnight or by installing back 
into the tube mount and not turning it on for a few hours. 

5. Re install the tube in reverse of the removal and plug the UV cable and power plug back in and turn the system on. 