OUTPUT SETTINGS
The output chart below is applicable for the following countries: UK, France,
Italy, Spain, Finland, Belgium, Greece, Portugal, Czech, Latvia, Lithuania,
Malta, Romania, Slovenia and Austria. For other countries see the sizing
charts at the end of these instructions.
To adjust, switch off the power, open outer cover using key provided. Using
the edge of the key, rotate “Ozone Output” control to the required setting
for the theoretical room size as indicated in the chart below. The theoretical
room volume is obtained by multiplying the actual room volume by the AC
Factor.
Example:
- Actual Room Volume = 28 m³, No. of Air Changes per hour = 6.
- 6 Air Changes per hour the AC Factor = 2
- Theoretical Room Volume = 28 x 2 = 56m³ therefore use line 30–59 (Set
the unit output to Low).
The actual ozone level reached in a room will depend on the room size,
temperature, humidity, the number of air changes, the operating time and
the output setting. Using these setting guidelines ensures that the ozone
level does not exceed the EU normal workplace levels of 0.1 ppm (in other
countries different levels may apply).
If you require a safety data sheet or more information please contact your
supplier.