Ozito SAC-2110 Скачать руководство пользователя страница 4

Adjusting The Output Pressure

The output pressure of the regulated pressure outlet can be 

adjusted to suit the air tool connected and the task at hand.

1.  To do so, first decrease the 

pressure to 0psi by turning 

the pressure regulator anti-

clockwise.

2.  Then turn the pressure 

regulator clockwise until the 

desired pressure is shown 

on the regulated pressure 

gauge.

WARNING! 

DO NOT ATTEMPT TO ADJUST/MODIFY 

THE SAFETY VALVE IN ANY WAY. THE SAFETY VALVE 

INSTALLED ON THIS AIR COMPRESSOR IS DESIGNED 

TO AUTOMATICALLY RELEASE PRESSURE IN CASE OF 

EXCESS PRESSURE BUILD UP IN THE TANK.

3. CONTROLS

OPERATION

Switching The Compressor On/Off

1.  To switch the compressor on, 

pull the on/off switch to the 

‘I’ position. Allow the motor 

to run and the tank to fill up.

Note:

 

The compressor will automatically cut off when the tank 

pressure reaches 8bar and will automatically start up again when 

the tank pressure drops to 6bar.

2.  To switch the compressor off, press the on/off switch to the ‘0’ 

position.

Thermal Overload Protection

This Air Compressor is fitted with thermal protection and will shut 

off to protect the compressor from overheating.

The compressor may also have shut off due to reaching max. 

cut off pressure. If you are unsure, use an attached blow gun to 

release some of the pressure until the tank pressure gauge drops 

below 6bar. If the motor does not automatically start up, the unit 

has overloaded and the thermal protection has activated.

If the thermal protection activates, switch off the compressor 

and allow the compressor to cool down for 15 minutes. Before 

attempting to restart the compressor, check that the air filter is not 

blocked. Refer to the Maintenance section to clean the air filter.

 

WARNING! 

ALLOW THE AIR COMPRESSOR TO COOL 

BEFORE ATTEMPTING ANY MAINTENANCE.

WARNING! 

DO NOT CONTINUE USE OF THE UNIT 

IF THE THERMAL PROTECTION ACTIVATES AGAIN 

IMMEDIATELY AFTER THE RESET.

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

1.0HP 21L 

SILENT

LOW MAINTENANCE

OIL FREE

TECHNOLOGY

ON

OFF

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

1.0HP 21L 

SILENT

LOW MAINTENANCE

OIL FREE

TECHNOLOGY

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

1.0HP 21L 

SILENT

LOW MAINTENANCE

OIL FREE

TECHNOLOGY

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

WARNING! 

THE AIR COMPRESSOR MUST BE USED 

WITH A RESIDUAL CURRENT DEVICE WITH A RATED 

RESIDUAL CURRENT OF 30mA OR LESS.

WARNING! 

DO NOT LEAVE THE AIR COMPRESSOR 

UNATTENDED WHILE THE ON/OFF SWITCH IS IN THE 

‘ON’ POSITION.

Содержание SAC-2110

Страница 1: ...rm maintenance as set out within the instruction manual If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 24L Silent Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts Air Filter Support Foot Small B...

Страница 2: ...zzles blower nozzles and paint guns The compressor is not suitable for tools with a high air consumption such as grinders or impact wrenches Pre Setup Checks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust ...

Страница 3: ...peat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools WARNING ENSURE YOU HAVE A FIRM GRIP ON THE AIR HOSE WHEN DISCONNECTING IT FROM THE AIR COMPRESSOR AS PRESSURISED AIR IN THE TANK MAY CAUSE IT TO WHIP AROUND AND INFLICT INJURY OR DAMAGE 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the ai...

Страница 4: ...tart up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes Before attempting to restart the compressor check that the air filter is not blocked Refer to the Maintenance section to clean the air filter WARNING ALLOW THE AIR COMPRESSOR TO COOL BEFORE ATTEMPTING ANY MAINTEN...

Страница 5: ...ILENT LOW MAINTENANCE OIL FREE TECHNOLOGY 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm AIR COMPRESSOR 1 0HP 21L SILENT LOW MAINTENANCE OIL FREE TECHNOLOGY 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESS...

Страница 6: ...ound 3bar 3 Unscrew the lid of the air filter 4 Remove the paper filter from the housing tap it and spray it with the blow gun to remove any dirt Re insert it into the housing 5 Re attach the lid 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm ...

Страница 7: ...R CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING No protection against ingress from water lP20 Sound Power Level Wear hearing eye and breathing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute psi L min Pounds per...

Страница 8: ...t of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a case of misuse The user and not the manufacturer shall be liable for any damage or injury resulting from such cases of misuse The manufacturer shall not be liable for any ch...