Ozito ROS-2000U Скачать руководство пользователя страница 7

size 445 x 210 mm

Danger!

 - Read the operating instructions to re-

duce the risk of inquiry

Caution! Wear ear-muffs.

 The impact of noise 

can cause damage to hearing.

Caution! Wear a breathing mask. 

Dust which 

is injurious to health can be generated when 

working on wood and other materials. Never use 

the device to work on any materials containing 

asbestos!

Caution! Wear safety goggles. 

Sparks gene-

rated during working or splinters, chips and dust 

emitted by the device can cause loss of sight.

The reprinting or reproduction by any other me-

ans, in whole or in part, of documentation and 

papers accompanying products is permitted only 

with the express consent of the iSC GmbH. 

Subject to technical changes

ROS-2000U

GB

  Additonal operating & safety instructions Random Orbital Sander

Service information

We have competent service partners in all countries named on the guarantee certificate whose contact 

details can also be found on the guarantee certificate. These partners will help you with all service re

-

quests such as repairs, spare and wearing part orders or the purchase of consumables.

Please note that the following parts of this product are subject to normal or natural wear and that the 

following parts are therefore also required for use as consumables.

Category

Example

Wear parts*

Carbon brushes, grinding/sanding plate

Consumables*

Grinding/sanding paper

Missing parts

* Not necessarily included in the scope of delivery!

In the effect of defects or faults, please register the problem on the internet at www.isc-gmbh.info. Plea

-

se ensure that you provide a precise description of the problem and answer the following questions in all 

cases:

• 

Did the equipment work at all or was it defective from the beginning?

• 

Did you notice anything (symptom or defect) prior to the failure?

• 

What malfunction does the equipment have in your opinion (main symptom)?   

Describe this malfunction.

 Yang/Product-Management

Weichselgartner/General-Manager

- 135 -

explains the following conformity according to EU directives and norms for 

the following product

Random Orbital Sander ROS-2000U (Ozito)

   2014/29/EU 

 2005/32/EC_2009/125/EC 
 2014/35/EU 
 2006/28/EC 

X  2014/30/EU 

 2014/32/EU 
 2014/53/EC 
 2014/68/EU 
 90/396/EC_2009/142/EC 
 89/686/EC_96/58/EC 

X  2011/65/EU

 X  2006/42/EC

 Annex IV

Notifi ed Body:

Notifi ed Body No.:

Reg. No.:

 2000/14/EC_2005/88/EC

 Annex V

 Annex VI

 Noise: measured L

WA

 =  dB (A); guaranteed L

WA

 =  dB (A)

P =  KW; L/Ø =  cm

Notifi ed Body:

 2012/46/EU

Emission No.:

Standard references:  EN 60745-1; EN 60745-2-4; EN 55014-1; 

EN 55014-2; EN 61000-3-2; EN 61000-3-3

Landau/Isar, den 28.06.2016

First CE: 16  

 

Archive-File/Record:

 NAPR014323

Art.-No.:

 44.722.45 

I.-No.: 11016 

Documents registrar:

 Robert Gehard

Subject to change without notice

 

Wiesenweg 22, D-94405 Landau/Isar

 ISC GmbH · Eschenstraße 6 · D-94405 Landau/Isar

Declaration of confirmity

Beiblatt_ROS_2000U.indd   1

28.06.2016   10:50:52

Содержание ROS-2000U

Страница 1: ...bly instructions or due to incorrect installation a failure to follow the operating instructions for example connecting it to an incorrect mains voltage or current type or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care and maintenance Damage to the device caused by abuse or incorrect use for example over...

Страница 2: ...h the holes on the sanding pad 5 Dust Bag 6 Hook Loop Sanding Sheet ACCESSORIES 1 On Off Switch 2 Hook Loop Backing Pad 3 Soft Grip 4 Dust Bag Adaptor RANDOM ORBITAL SANDER SETUP PREPARATION 2 Replace the sanding sheet when it is worn 3 Replace hook loop backing pad when worn see maintenance section Ensure the tool is disconnected from the power supply before performing any of the following operat...

Страница 3: ...he extraction port 1 Push the dust bag onto the dust extraction port aligning the locking tab and rotate as shown OPERATION Install The tool is recommended for use with a residual current device with a rated residual current of 30mA or less 1 3 3 Empty dust bag when it becomes 1 3 full for optimum dust extraction CAUTION GUIDE THE CORD DURING SANDING TO PREVENT IT BEING CAUGHT ON THE WORKPIECE OR ...

Страница 4: ...ard 2 Firmly grasp the sander and switch it on Let the motor build up to maximum speed 3 Gradually lower onto the workpiece with a slight forward movement 4 For optimum results use either of these stroke patterns 1 Secure the material to be sanded ...

Страница 5: ...ll produce a smoother finish The condition of the workpiece will determine the grit of the sandpaper to be used The higher the grit number the finer the grade of sandpaper If the surface is rough start with a coarse grit and sand until the surface is uniform Medium grit may then be used to remove scratches left by the coarser grit Finer grit is then used to finish the surface Always continue sandi...

Страница 6: ...s enables better control of the power tool in unexpected situations f Dress properly Do not wear loose clothing or jewellery Keep your hair clothing and gloves away from moving parts Loose clothes jewellery or long hair can be caught in moving parts g If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used Use of dust col...

Страница 7: ...ding plate Consumables Grinding sanding paper Missing parts Not necessarily included in the scope of delivery In the effect of defects or faults please register the problem on the internet at www isc gmbh info Plea se ensure that you provide a precise description of the problem and answer the following questions in all cases Did the equipment work at all or was it defective from the beginning Did ...

Страница 8: ...tions determined in accordance with EN 60745 Handle Vibration emission value ah 4 035 m s2 K uncertainty 1 5 m s2 The specified vibration value was established in accordance with a standardized testing method It may change according to how the electric equip ment is used and may exceed the specified value in exceptional circumstances The specified vibration value can be used to compare the equipme...

Отзывы: