background image

AC

DC

I

0

I

+

MODE

I

The purchased battery will be shipped in a low charge condition, and requires charging 
prior to use. Allow several cycles of charging and discharging (through use of the tool) 
for the battery to reach its optimum performance / runtime.

1    Connect the charger into a mains power outlet.

4  The charger LED will illuminate 

red signifying that the battery is 

charging.

3   With the charger sitting on a flat 

surface, align the raised ribs on 

the battery with the recess in the 

charger and slide onto the charger 

ensuring a firm connection.

2   The charger LED will flash green 

showing power is being supplied 

to the charger.

5  The charger LED will illuminate 

green once the battery is fully 

charged.

Charging your lithium ion battery - Fast Charger

Charger LED Indicator 

LED Indicator 

Situation

GREEN (Flashing) 

Stand By (no battery pack is inserted) 

RED (Flashing)

Battery is charging (low charge)

RED (Illuminated)

Battery is charging (mid charge)

GREEN (Illuminated)

Battery is fully charged

BOTH(Illuminated)

Battery pack is too hot or too cold (charging will begin 
automatically when battery reaches correct charging 
temperature).

BOTH (Flashing)

Defective battery. Never charge a defective battery 
pack!
Remove battery pack from charger.

1.  BATTERY & CHARGING 

(sold separately)

KNOW YOUR PRODUCT

SETUP & PREPARATION

HYBRID INFLATOR / DEFLATOR

ACCESSORIES

1

2

3 4

9

10

11

5 6

7

8

1  Adapter Compartment

2  Power Mode Switch

3   Pressure Selection Buttons

4  Battery Seating

5  Operation Mode Switch

6  Carry Handle

7  Power Cord Compartment

8  High Volume Air Hose

9  Presta Adapter

10  General Purpose Adapter

11  Ball Adapter

CAUTION:

 

THE CHARGER FOR THIS PRODUCT 

SHOULD BE PROTECTED BY A RESIDUAL CURRENT 
DEVICE (RATED AT 30mA OR LESS).

ONLINE MANUAL 

Scan this QR Code with your 

mobile device to take you to the 

online manual.

BATTERY & CHARGER (sold separately)

This tool is compatible with all batteries and chargers from the Ozito 

Power X Change Range.

Содержание PXHDIS-240

Страница 1: ...ure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure Generally you will be responsible for all costs associated with a claim under this warranty however where you have suffered any additional direct loss as a result of...

Страница 2: ...ing Battery is charging low charge RED Illuminated Battery is charging mid charge GREEN Illuminated Battery is fully charged BOTH Illuminated Battery pack is too hot or too cold charging will begin automatically when battery reaches correct charging temperature BOTH Flashing Defective battery Never charge a defective battery pack Remove battery pack from charger 1 BATTERY CHARGING sold separately ...

Страница 3: ...hing Stand By no battery pack is inserted RED Illuminated Battery is charging low charge GREEN Illuminated Battery is fully charged RED Flashing Battery or Charger fault RED GREEN Flashing Battery pack is too hot or too cold remove battery from charger and store at room temperature 20ºC Insert battery again when at correct charging temperature If this happens again the battery is defective and nee...

Страница 4: ...lating a high pressure item the current pressure will be displayed on the digital display Note When using the inflator to inflate or deflate a high volume item the digital display will show 0 00 2 Increase the preset pressure using the button or decrease the pressure using the button The preset pressure will be displayed on the digital display as it is adjusted 1 To change between the 3 pressure m...

Страница 5: ...emove the high volume air hose from the housing and attach to the inlet port 3 Adjust the target pressure using the and pressure adjustment buttons Note The required pressure should be written on the item 5 Once the preset pressure is reached the tool will automatically shut off After the tool has automatically shut off press the operation mode switch into the off position 0 2 Insert attach the ho...

Страница 6: ...lator is not operating at full capacity Possible clogging Ensure the air inlet is not blocked when inflating a high volume item Ensure the air outlet is not blocked when deflating a high volume item Loose hose of adaptor Ensure the hose or inflation adaptor is fitted securely Motor stops while inflating Battery has no power Charge battery High pressure item has reached preset pressure The inflator...

Страница 7: ...ssembly may result in a risk of electric shock electrocution or fire 9 To reduce risk of electric shock unplug the charger from the outlet before attempting any cleaning Removing the battery pack will not reduce this risk 10 Never attempt to connect 2 chargers together 11 DO NOT store or use the tool and battery pack in locations where the temperature may reach or exceed 40ºC such as inside sheds ...

Страница 8: ...ose clothes jewellery or long hair can be caught in moving parts g If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used Use of dust collection can reduce dust related hazards 4 Power tool use and care a Do not force the power tool Use the correct power tool for your application The correct power tool will do the job be...