litHium ion Battery and cHarGer Safety featureS
8
over current protection
If the battery (8) is overloaded and the maximum current draw is exceeded the
battery will temporarily stop working to protect the internal components. The
battery (8) will resume normal operation once the current draw has returned to its
normal safe level. This may take a few seconds.
Short circuit protection
If the battery (8) short circuits, the short circuit protector immediately stops the
battery (8) from operating.
This ensures that no internal components of the battery (8) or tool are damaged.
charging your Battery
The drill’s battery (8) has been shipped in a low charge condition, and requires
charging prior to use.
Connect the charging jack (10) to the charging
port (7) (Fig. 1).
Plug the charging adaptor (9) into a mains
power outlet.
The battery charge indicator (5) will illuminate
showing that power is being supplied.
The battery takes 3 – 5 hours to charge. Charging
starts automatically.
Once the battery is fully charged, the battery charge indicator (5) will go off.
caution:
Disconnect the charger adaptor from the mains power when charger is not
in use.
important charging notes
The charging adaptor (9) and battery (8) may become warm to touch while
charging. This is a normal condition, and does not indicate a problem.
Use the charger at normal room temperature whenever possible. To prevent
overheating, do not cover the charger and do not charge the battery pack in
direct sunlight or near heat sources.
If the battery (8) does not charge properly:
- Check current at mains power outlet by plugging in a lamp or other appliance.
- If charging problems persist, have the complete tool checked by an electrician
or a power tool repairer.