Ozflame oZF 100B Скачать руководство пользователя страница 5

B i o - F u e l   F i r e p l a c e s

Children, animals and infirm persons should not be left 
unattended near the fireplace when lit. Only adults who 
have read instructions and are familiar with procedures 
should add fuel or light or extinguish the fire.

Never place the burner or fireplace near flammable 
objects such as clothing, curtains etc, or other flammable 
materials etc. The following clearances are recommended 
– 1 metre from any fabric (curtains etc) or flammable 
material, 1.5 metres from ceilings, 40 cm from walls 
(unless fireplace is designed to go against a wall or is wall 
mounted). Models OZF100 & OZF105 are designed 
for free-standing, indoor applications and can be located 
against a wall.

As the fireplace consumes oxygen, there is a danger of suffocation, so the fireplace should be located 
in a suitably sized room with adequate oxygen supply and fresh air.  The first signs of lack of oxygen are 
sudden fatigue and an impaired ability to concentrate.

FIRE

BLANKET

  

Wall

Ceiling

Fabr

ic/C

ur

tains

40cm

1m

1.5m

5L

1.8/3L

FUEL

FIRE 

EX

TINGUISHER

recommended  

clearance

For burners up to 3 litres in  

size, room size should be a minimum of 35m

3

For burners over 3 litres in size,  

the room size should be a minimum of 70m

3

FIRE

BLANKET

  

Wall

Ceiling

Fabr

ic/C

ur

tains

40cm

1m

1.5m

5L

1.8/3L

FUEL

FIRE 

EX

TINGUISHER

MiNiMuM 70m

3

FIRE

BLANKET

  

Wall

Ceiling

Fabr

ic/C

ur

tains

40cm

1m

1.5m

5L

1.8/3L

FUEL

FIRE 

EX

TINGUISHER

MiNiMuM 35m

3

Содержание oZF 100B

Страница 1: ...p l a c e s User Information and Instruction Manual www ozflame com au 27 Rosalie Street SpringvaleVIC 3171 Australia t 61 0 3 9562 3455 f 61 0 3 9548 3979 e sales thermofilm com au www thermofilm com...

Страница 2: ...nless steel side inserts tempered glass oZF 200 series oZF 200 Floor mount free standing indoor and outdoor with 5L fire box 490H x 700L x 450Dmm Stainless steel tempered glass oZF 210B oZF 210W Floor...

Страница 3: ...ndoor and outdoor with 3L fire box 400H x 780L x 290Dmm Powder coated steel tempered glass oZF 500 series oZF 502 1 8L fire box stainless steel 70H x 240L x 120Dmm oZF 503 3L fire box stainless steel...

Страница 4: ...or fireplace Do not put any foreign objects in the fireplace particularly cigarette butts Always store bio fuel in a sealed container designed for this purpose Do not ingest bio fuel If ingested or sp...

Страница 5: ...st a wall or is wall mounted Models OZF100 OZF105 are designed for free standing indoor applications and can be located against a wall As the fireplace consumes oxygen there is a danger of suffocation...

Страница 6: ...esistant foam or carbon dioxide are suitable extinguishing agents Do not use water to put out the flames Fireplace location Depending on your Ozflame model the fireplace should be located in an approp...

Страница 7: ...rmation centre Australia phone 0800 764 766 Filling the burner We recommend that you remove the burner from the fireplace and fill it outdoors to reduce any spillage hazard Fill the burner in the fire...

Страница 8: ...ner rather than close the slider before all fuel is used Fuel level must be a minimum of 1 3 full before lighting For models with glass fitted on 4 sides we recommend removing the front piece of glass...

Страница 9: ...ecome slightly stiff to close In this case push the slide firmly and quickly and it will extinguish the flame Make sure there are no flames around the edges of the slide If this occurs push the slide...

Страница 10: ...event of damage or accident resulting from negligence lack of care or maintenance or if the fireplace has been modified in any way Glass breakage is not included in the warranty Due to the high tempa...

Страница 11: ...B i o F u e l F i r e p l a c e s...

Страница 12: ...27 Rosalie Street SpringvaleVIC 3171 Australia t 61 0 3 9562 3455 f 61 0 3 9548 3979 e sales thermofilm com au www thermofilm com au www ozflame com au...

Отзывы: