OZCO Project 120 Скачать руководство пользователя страница 10

V2.00 - Installation Instructions, Specifications and Project Plans are effective 3/12/2018 . This information is updated periodically 
and should not be relied upon after 2 years from 3/12/2018 . Please visit OZCOBP.com to get current information.

ITEM 

NO.

QTY.

PART NUMBER

DESCRIPTION

1

2

2x8 Cedar 

Board

2x8x10'0"

2

19

2x2 Cedar 

Board

2x2x10'0"

3

2

6x6 Cedar Post

6x6x3'6"

4

2

6x6 Cedar Post

6x6x3'0"

5

2

6x6 Cedar Post

6x6x1'0"

6

2

6x6 Cedar Post

6x6x8'0"

7

2

6x6 Cedar Post

6x6x2'4"

8

2

6x6 Cedar Post

6x6x4'0"

9

2

56633

6x6 Post Anchor Kit (6x6-

OPAK-LS)

10

4

56646

Truss Base Fan 3 Point (TBF-3-

PT)

6

  51711

Truss Accent (TA-IW)

0.08

    56625

Screw, OWT 1-3/4" (45mm) 

Timber

11

4

56614

Flush Outside 90° (FI-90)

8

  51711

Truss Accent (TA-IW)

0.08

    56625

Screw, OWT 1-3/4" (45mm) 

Timber

12

1

56627

Screw, OWT 3-3/4" (95mm) 

Timber with HCN

1

  56621

1 1/2" Hex Cap Nut (HCN)

13

1

56615

Flush Inside 90 (FI-90)

2

  51711

Truss Accent (TA-IW)

0.08

    56625

Screw, OWT 1-3/4" (45mm) 

Timber

14

2

56616

Flush Inside 45 (FI-45)

4

  51711

Truss Accent (TA-IW)

0.08

    56625

Screw, OWT 1-3/4" (45mm) 

Timber

Material List

Material List

Bill of Material-Design 1

OZCO Project #120 IW - BBQ Arbor Cover

10

QTY.

PART 

NUMBER

DESCRIPTION

2

2x8x10L

2x8x10

19

2x2x10L

2x2x10

1

6x6x6L

6x6x6

5

6x6x8L

6x6x8

2

56633

6x6 Post Anchor Kit (6x6-OPAK-LS)

8

56614

Flush Outside 90° (FO-90)

28

51711

Truss Accent (TA-IW)

5

56625

OWT Timber Screw 1-3/4"

1

56627

Screw, OWT 3-3/4" (95mm) Timber 
with HCN

1

56621

1 1/2" Hex Cap Nut (HCN)

1

56615

Flush Inside 90

2

56616

Flush Inside 45 (FI-45)

4

56646

Truss Base Fan 3 Point (TBF-3-PT)

Содержание Project 120

Страница 1: ...effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information OZCO Project 120 BBQ Arbor Cov...

Страница 2: ...Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information OZCO Project 120 BBQ...

Страница 3: ...Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information OZCO Project 120 BBQ...

Страница 4: ...Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information OZCO Project 120 BBQ...

Страница 5: ......

Страница 6: ...updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information 8 11 16 3 11 16 7 8 3 8 6 5 9 16 2 4 4 0 2 1 2 typ 1 0 8 0 10 0 5 9 11...

Страница 7: ...ormation is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information 1 3 3 4 6 0 1 0 3 3 8 typ 3 4 1 2 4 7 8 Overview Design 2...

Страница 8: ...and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information C L 6 3 5 11 1 11 1 11 1 2 3 9 16 7 1 2 3 1 X 45 8 8 2 4 9 16 C L 1 2 X 45 8 1 2 8 1 2 4 3...

Страница 9: ...s are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information Bill of Material Design 1...

Страница 10: ...6614 Flush Outside 90 FI 90 8 51711 Truss Accent TA IW 0 08 56625 Screw OWT 1 3 4 45mm Timber 12 1 56627 Screw OWT 3 3 4 95mm Timber with HCN 1 56621 1 1 2 Hex Cap Nut HCN 13 1 56615 Flush Inside 90 F...

Страница 11: ...ffective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information 51711 56625 56627 56621 56633 56...

Страница 12: ...m 3 2 2017 Please visit OZCOBP com to get current information ITEM NO QTY PART NUMBER DESCRIPTION 1 4 4x4 Cedar Post 4x4x8 0 2 4 2x6 Cedar Board 2x6x6 0 3 12 2x4 Cedar Board 2x4x8 0 4 4 56632 4x4 Post...

Страница 13: ...roject Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information 51775 OZCO Pro...

Страница 14: ...M NO QTY PART NUMBER DESCRIPTION 1 4 4x4 Post 4x4x8 0 2 6 2x4 Board 2x4x2 0 3 19 2x4 Board 2x4x4 0 4 6 2x2 Board 2x2x2 0 5 36 2x2 Board 2x2x10 0 6 4 2x2 Board 2x2x6 0 7 4 2x6 Board 2x6x10 0 8 4 56641...

Страница 15: ...ect Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information 51731 51717 OZCO...

Страница 16: ...d Project Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information Translucent...

Страница 17: ...d Project Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information Translucent...

Страница 18: ...d Project Plans are effective 3 2 2017 This information is updated periodically and should not be relied upon after 2 years from 3 2 2017 Please visit OZCOBP com to get current information Translucent...

Отзывы: