OC-SR30 Manual - Rev 1.0
SPECIFICATIONS
1
Electrical Parameters
1-1
Normal input solar cell array voltage :
17 - 22
Typ.
Vdc
1-2
Max. solar cell array voltage (when output has no load)
25
Max.
Vdc
1-3
Current consumption when connected 15V Array (battery not present) :
35
Max.
mAdc
1-4
Current consumption when connected 12V battery (Array not present) :
25
Max.
mAdc
2
Output Control & metering Characteristics
2-1
Charging Method: Level 1
→
Level 2
→
Level 3
2-2
Minimum charging condition for Start Up
2-2-1
Correct polarity at input and output;
2-2-2
Charging starts when Battery voltage is not less than
5.0
+/-0.3
Vdc
2-2-3
Minimum solar cell array voltage
13.0
+/-0.3
Vdc
2-2-4
Solar cell array voltage is higher than battery voltage
1.0
+/-0.3
Vdc
2-3
Maximum Charging Current at Level 1 period
30.0
+/-1.0
Adc
2-4
Maximum charging voltage at Level 2 Period ( for GEL Battery)
14.4
+/-0.4
Vdc
2-5
Maximum charging voltage at Level 2 Period (for LEAD-ACID Battery)
14.7
+/-0.4
Vdc
2-6
Level 1 to Level 2 Period when charging voltage reach (for GEL Battery)
14.1
+/-0.4
Vdc
2-7
Level 1 to Level 2 Period when charging voltage reach (for Lead-Acid Battery)
14.5
+/-0.4
Vdc
2-8
Level 2 to Level 3 Period when charging current reach (for GEL Battery)
4.0
+/-1.0
Adc
2-9
Level 2 to Level 3 Period when charging current reach ( for Lead-Acid Battery)
4.0
+/-1.0
Adc
2-10
Maximum charging voltage at Level 3 Period
13.8
+/-0.4
Vdc
2-11
LCD Meter Accuracy at DC Voltage
1.25
%
2-12
LCD Meter Accuracy at DC Current at 5 ~30Amp
3
%
3
Protection
3-1-1
Over temperature protection active at above
85
o
C
3-1-2
The charger will resume the charging at about
65
o
C
4
Electrical Parts
4-1
Input / Output Terminals
M5 Terminals
5
Physical Parameters
5-1
Panel material :
Plastic, Standard ABS
5-2
Panel Dimension :
175 (W) x 110 (H) mm
5-3
Panel Cut Out Size:
159 (W) x 95 (H) mm
5-4
Overall Depth :
approx. 45 mm
5-5
Net weight :
approx. 360g
6
Environmental Characteristics
6-1
Operating temperature :
-5 to 45
o
C
6-2
Storage temperature :
-10 to 70
o
C
6-3
Operating Humidity range :
0 to 80% RH
2 YEAR MANUFACTURER WARRANTY
Zylux Distribution Pty. Ltd. (OzCharge) warrants to the Customer that this product is substantially free from defects in materials and
workmanship under normal use for a period of 2 Years from the Date of Purchase.
Please ensure you keep a copy of your receipt on file as this will be required for proof of purchase and to validate your warranty.
Obtaining Warranty Service
Within the warranty period, the Customer must contact the authorised supplier / retailer where the product was purchased or
alternatively you can contact the OzCharge service centre through one of the following methods:
Hotline
: (03) 9482 2203
Website
:
www.ozcharge.com.au
If the Authorised Supplier and / or OzCharge service centre concludes that while under normal use, a product failure or malfunction
occurred during the warranty period and was caused by a defect in material or workmanship (see Exclusions), the Customer will be
asked to ship to the nearest service point. The product must be packaged appropriately for safe shipment. To prove that the product is
under warranty, the customer should enclose a copy of their receipt for proof of purchase. It is recommended that returned products be
sent by registered mail as Zylux Distribution Pty Ptd. (OzCharge) accepts no responsibility / liability for goods lost or damaged in transit.
Return Shipping costs to be incurred by the Customer.
Exclusions
If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the
product does not exist or was caused by the Customer or any third persons misuse, physical abuse, water damage, unauthorised
attempts to open, repair or modify the product or improper installation, this will not be covered under this warranty.
This Warranty is void if:
1. The product has been tampered or repaired by unauthorised personnel.
2. The warranty seal is broken or altered.
3. The warranty period has expired.