DD-75-193 R(0)
Y.T
.31.03.17
2
INDEX
1. GENERAL INFORMATION .............................................................................................................................................. 3
1.1.
Glass Line A1 Technical Specifications
1.2.
Glass Line A2 Technical Specifications
2. SAFETY AND OPERATION .............................................................................................................................................. 7
2.1.
Safety Warnings And Symbols
2.2.
Power Supply Fuse Replacement
2.3.
Safety Related Instructions
2.4.
Operating Precautions
3. HANDLING AND INSTALLATION .................................................................................................................................... 8
3.1.
Handling
3.2.
Installation
4. SETUP AND OPERATION ................................................................................................................................................ 10
4.1.
Power and Grounding Connections
4.2.
Control Board Connections
4.3
Control Board Settings
4.3.1 Blocking Passage Direction
4.3.2 Timeout and Mode Settings by Dip Switch
4.4.
Operating Instructions
5. POST INSTALLATION CHECK LIST .................................................................................................................................. 12
6. SERVICE AND MAINTENANCE ....................................................................................................................................... 13
6.1.
Maintenance Instructions
6.1.1. Recomended User Maintenance
6.1.2. Periodic Maintenance by Technical Service Personnel
6.2.
Trouble Shooting Guide
6.3. Motor Driver Adjustments
6.4. Photo Sensor Replacement and Alignment
6.5. Motor Replacement
6.6.
Schematic Diagram
7. LIST OF REPLACEMENT PARTS ...................................................................................................................................... 19
8. CE DECLARATION OF CONFORMITY AND WARRANTY ................................................................................................ 20
8.1.
Warranty Certificate
8.2.
Warranty Terms and Conditions
8.3.
Cases Excluded From The Coverage of Warranty
8.4.
Declaration of CE Compliance
GLASS LINE A1
TECHNICAL SPECIFICATIONS
DD-72-147 R(16)
1 / 2
Y.T.04.04.2017
Power Requirements :
110/220-240V. 60/50Hz. AC (%±10) 24V.DC at standby ~2W.max. ~65W. System is
powered by a well regulated SMPS which can automatically compensate for voltage fluctuations.
Dimensions
:
Cylindrical body 1030mm x Ø230mm x Wing width (550 / 900mm)
Body Features
:
1mm thick, single piece, 304-Grade satin finished stainless steel cylindrical body.
Wing Features
:
Wing is made of 10 mm thick tempered glass (Opt.polycarbon or acrylic). 550 mm or
900 mm wing lengths are available as standard choices.
Top Lid Features
:
Standard 20mm thick natural granite (Star Galaxy Black) stone top lid for a decorative
and aesthetical appearance (opt. tempered glass, stainless steel, wood).
Indicator Features :
Built-in circular RGB LED status indicators are located under the top lid. Illumination is
blue at stand-by; green during authorised passage, flashing red for unauthorised
attempts and green for emergency alert mode.
Operating Temperature, Humidity, IP Rating, MCBF
:
-20°C - +68°C (Opt. -50°C with heater unit) / RH 95% non-condensing /IP 44 Indoor
Model (IP 56 is available for optional pipe wing versions)/ 1M Cycles.
Control System
:
All inputs are opto-coupler protected. Controlled by dry contact or grounding input.
Compatible with all access control systems that provide dry contact or grounding
outputs. Optional RS232/RS485/TCP IP control module is available.
Weight
: ~58kg (with 90 cm. tempered glass wing and granite top cover).
Содержание GL A1