If the level of water sinks too far, any sludge in the shaft will dry out 
quickly to stop the pump from starting up. It is necessary, therefore, 
to check the submersible motor pump regularly (by carrying out start 
up tests). 
The floater is adjusted in a way that the pump can immediately be 
started. 
NOTE: The pump shaft should have minimum dimensions of 
40x40x50cm, so that the floating switch can move freely. 

MAINS SUPPLY

 

Your new submersible pump is equipped with a shockproof plug 
according to regulations. The pump is designed to be connected to a 
230V~, 50Hz safety socket. 
Make sure that the socket is sufficiently secured (min.6Amp.) and is 
in excellent condition. Introduce the plug into the socket and the 
pump is ready to go. 

IMPORTANT NOTE: If the mains cable or plug suffers any damage 
from external action, repairs to the cable are prohibited. 
NOTE: This work may only be performed by a qualified electrician or 
customer service. 

AREAS OF USE

 

This pump is used primarily as cellar pump. When installed in a shaft, 
this pump provides protection from flooding. 

They are also used wherever water has to be moved from one place 
to another, e.g. in the home, agriculture, horticulture, plumbing and 
many other applications. 

SETTING TO WORK

 

After having read these instructions carefully, you can set your pump 
to work, reconsidering the following item: 
 
• Check if the pump rests on the ground of the shaft. 
• Check if pressure cord has been attached properly. 
• Check if electrical connection is 230V~, 50Hz. 
• Check if socket is in good condition. 
• Make sure that the water and humidity can never come to the 
mains supply. 
• Avoid pump running dry. 