background image

OX- A Series 

OXYGEN CONCENTRATOR 

OX-10A/5A Oxygen Concentrator 
Instruction   Guide 
VERSION NO: VO 

Issued on 2016.3.10

 

WARNING-Read instruction guide before operating this equipment. 

DANGER---NO SMOKING 

Page 1 of 16 

Содержание OX- A Series

Страница 1: ...A Series OXYGEN CONCENTRATOR OX 10A 5A Oxygen Concentrator Instruction Guide VERSION NO VO Issued on 2016 3 10 WARNING Read instruction guide before operating this equipment DANGER NO SMOKING Page 1 of 16 ...

Страница 2: ...S OF YOUR OXYGEN CONCENTRATOR 5 SETTING UP YOUR OXYGEN CONCENTRATOR 6 BEFORE OPERATING YOUR OXYGEN CONCENTRATOR 7 OPERATING YOUR OX 10A 5A OXYGEN CONCENTRATOR 7 RESERVE OXYGEN SYSTEM 8 CARING AND PERIODIC MAINTENANCE FOR YOUR UNIT 9 MINOR TROUBLESHOOTING 12 SPECIFICATIONS 13 SYMBOL 14 ELECTROMAGNETIC IMMUNITY 15 DECLARATION OF CONFORMITY 16 Page 2 of 16 ...

Страница 3: ...e using an oxygen concentrator is advisable Physician Information Physician Name Telephone Address Prescription Information Name Oxygen liters per minute at rest during activity Other Oxygen use per day Hours Minutes Comments OX B series oxygen Concentrator Serial Number check one 10 Liter 5 Liter OXTM Provider Information Service Person This instruction guide was reviewed with me and I have been ...

Страница 4: ... your physician DANGER Oxygen causes rapid burning Do not smoke while your oxygen concentrator is operating or when you are near a person utilizing oxygen therapy Do not use within 5 feet 1 6m of hot sparking objects or naked sources of flame WHY YOUR PHYSICIAN PRESCRIBED SUPPLEMENTAL OXYGEN Today many people suffer from heart Lung and other respiratory diseases Many of these people can benefit fr...

Страница 5: ...ectrical overload shutdown 3 Humidifier Holder 4 Oxygen outlet oxygen is dispersed through this port 5 Flow meter control button M increase flow reduce flow 0 5 LPM per scale 6 Timing setting increase reduce 30 min per step 7 Monitor indicate the condition of oxygen purity status and hour meter 8 Green Power light illuminates when your concentrator is operating 9 Normal Oxygen green light the LED ...

Страница 6: ...or naked sources of flame NOTE Do not connect to an electrical outlet controlled by a wall switch NO other appliances should be plugged into the wall outlet 2 Position your unit at least 6 inches 16 cm from walls draperies or any other objects that might prevent the proper flow of air in and out of your oxygen concentrator The Oxygen concentrator should be located so as to avoid pollutants or fume...

Страница 7: ... tubing directly to the connector Figure 3 Figure 1 Oxygen Tubing Connection with Humidification a If your physician has prescribed an oxygen humidifier as part of therapy b Follow these steps c Fill the humidifier bottle with distilled water Do not overfill d Attach the oxygen tubing directly to the humidifier bottle outlet fitting Figure 4 Figure 2 Your physician has prescribed either a nasal ca...

Страница 8: ...there is no power to the unit Refer to the Minor Troubleshooting chart not page 8 and contact your OXTM provider if necessary NOTE If an audible low frequency vibration sound is detected the unit is not operating properly Refer to the Minor Troubleshooting chart on page 8 and contact your OXTM provider if necessary 2 Check the flow meter to make sure that the flow meter ball is centered on the lin...

Страница 9: ...roughly with warm tap water and towel dry The filter should be completely dry before reinstalling Air filter need to be replaced after device operates each 3000 hours Air filter is disposable after used Not replace the air filter regularly will affect the performance of concentration CAUTION To prevent product damage do not attempt to operate the unit without the air filter or while the filter is ...

Страница 10: ...close the Important Safeguard 3 Change the Bacterial Filter at least once a year You can not change this by yourself you must contact your OXTM Medical provider change this for you Page 10 of 16 ...

Страница 11: ... B series Device is a device within your concentrator that monitors the oxygen produced by your unit When the units is turned ON all lights Power Normal Oxygen Low Oxygen and Service Required on the front panel will illuminate briefly After few seconds only the Power and Normal Oxygen lights will remain lit The lights on the front panel are defined as follows Green LED Acceptable oxygen concentrat...

Страница 12: ...the oxygen outlet If proper flow is obtained clean or replace humidifier 5 Flow meter set too low Set flow meter to prescribed flow rate If the above remedies do not work contact your OXTm provider C Unit operates the power light is on when power switch is on audible low frequency vibration sound is detected Turn your unit off Switch to your reserve oxygen system and contact your OXTm provider imm...

Страница 13: ...to 95 Atmospheric pressure 50 106 kpa 7 3 15 4 psi 7 Weight 18 9kg OX 10A 14 9kg OX 5A 8 Sound Level ISO 8359 1996 from front 55dbA OX 10A 43dbA OX 5A 9 Dimensions 342mm L x368mm W x572mm H 10 Operating System Time Cycle Pressure Swing 11 Storage Conditions Temperature 40 to 70 Humidity 10 t0 100 Atmospheric pressure 50 106 kpa 7 3 15 4 psi 12 Equipment Class and Type The type of protect against e...

Страница 14: ...ne should be treated on local law or regulation requirement To avoid hurt users and pollute environment The equipment bears CE mark CE2460 indicating its conformity with the provision of Council Directive 93 42 EEC concerning medical devices and fulfills the essential requirement of Annex I of this directive FRAGILE Contents of the transport package are fragile therefore it shall be handled with c...

Страница 15: ...from fixed RF transmitters as determined by an electromagnetic site survey ashould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic is affected by absorption and reflec...

Страница 16: ...5A CGI Business Trading and Consulting e K Hans Bethe Str 1 60438 Frankfurt am Main Germany Tel 49 69 1752 6970 49 1785 647380 Fax 49 0 69 1534 6558 Email cgi trading consulting hotmail com Page 16 of 16 ADDRESS 10 2 Guang Long Industrial Park South 1st Rd Chencun town Shunde district Foshan city Guang Dong Province China ...