8.

 

CONNECTION OF THE UNIT 

 

Mains supply, control panel cable and, if necessary, comfort function connector should be connected 
to the Unit, according to the following diagram: 

 

 

 

 

 

 

 

 

Figure 6. Connection of the Unit 

 

IMPORTANT!

 Number and purpose of connections depends on device configuration: 

*1 – if internal preheater is not present 

*2 – if option selected prior ordering the Unit 

*3 – if option selected prior ordering the Unit 

 

IT IS PROHIBITED

 to connect any cables or devices to the connectors of the control panel and comfort 

functions, despite similarity to  any standard connectors. External similarity of  connectors does not 
guarantee compatibility – connected devices may fail or damage the Unit. Failure of the Unit due to 
incompatible supplementary parts connection will void the warranty! 

IT IS PROHIBITED

 to connect or disconnect control panel or WiFi controller without turning off the 

mains power first. The failure of the control panel or the Unit due to improper connection will void 
the warranty! 

 

 

 

- control panel or WiFi controller connector (USB) 

- comfort functions connector (RJ-45) 

- Mains cable (230V, 3x1.5mm

2

 L+N+PE) 

- el. preheater cable (*1) (230V, 3x1.5mm

2

 L+N+PE) 

- el. damper actuator (*3) connector 

- el. heater cable (*2) (230V, 3x1.5mm

2

 L+N+PE) 

Содержание X-Air V500

Страница 1: ...Rev 1 2 2021 04 INSTALLATION AND OPERATION MANUAL Heat Recovery Unit OXYGEN X Air V500...

Страница 2: ...1...

Страница 3: ...board electrical wiring diagram 21 8 5 Description of control board contacts 22 9 OPERATION OF THE UNIT 23 9 1 WiFi controller 23 9 1 1 Downloading the app 23 9 1 2 WiFi connection set up 24 9 1 3 App...

Страница 4: ...of packages matches with the consignment documentation Upon noticing any non conformity or damage of the package tears dents or compressed box detached or reattached packaging tape inform the courier...

Страница 5: ...ery Unit OXYGEN X Air V500 1 pc Control panel 10m connection cable included or WiFi adapter 1 pc Fastening elements Mounting bracket 1 pc Condensate drain nozzle 32 1 pc Condensate drain gasket 25 1 p...

Страница 6: ...ended to be used by persons including children with reduced physical sensory or mental capabilities unless they have been instructed to use the Unit and under constant supervision of person held respo...

Страница 7: ...014 ES 1254 2014 ES 2017 1369 EN 13141 7 2010 2010 30 EU labelling and standard product information of the consumption of energy and other resources by energy related products ES 1254 2014 2011 65 EU...

Страница 8: ...heat recovery 85 4 h Maximum flow rate m3 h 500 i Electric power input of the fan drive including W 252 j Sound power level LWA 53 k Reference flow rate m3 s 0 097 l Reference pressure difference Pa...

Страница 9: ...on W 100 100 500 252 0 150 484 251 6 200 463 251 1 250 443 249 9 300 422 248 7 350 398 247 4 400 374 245 8 450 344 242 5 500 314 239 0 70 50 337 106 0 75 325 105 8 100 313 105 1 125 298 104 9 150 283...

Страница 10: ...9 50 20 231 49 0 30 224 48 8 40 218 48 5 50 212 48 2 60 206 47 8 70 199 47 6 80 191 47 3 90 183 47 2 100 176 46 9 110 165 46 6 Measured with M5 class filters installed...

Страница 11: ...setting Air duct Sound power level LWA Octave band Hz Total 125 250 500 1000 2000 4000 8000 50 Suppply Extract Outside Exhaust 70 Suppply Extract Outside Exhaust 100 Suppply Extract Outside Exhaust M...

Страница 12: ...sions and weight Figure 1 Unit dimensions Body dimensions and weight Width mm Height mm Depth mm Weight kg OXYGEN X Air V40 750 677 492 32 OXYGEN X Air V500 left side version OXYGEN X Air V500 right s...

Страница 13: ...to humidity level indoors Disabling of supply or exhaust air stream Filtration G4 EN 779 2012 COARSE 65 ISO 16890 exhaust air filtering only G4 Carbon EN 779 2012 EPM2 5 60 ISO 16890 retains average s...

Страница 14: ...nit to the building s internal sewerage system Operating conditions 15oC 30oC relative air humidity 60 The Unit should be installed vertically Mounting bracket provided should be used to fasten Unit t...

Страница 15: ...ion duct incline refer to Figure 2 Air intake duct connection diagram should be ensured or other sufficient measures taken to prevent ingress of outdoor humidity or precipitation into the Unit IMPORTA...

Страница 16: ...en firmly screw the nozzle in by hand Figure 4 Installing the condensate drain IMPORTANT Do not use pliers or other similar tools as excess power applied may damage the Unit Mechanical damage will voi...

Страница 17: ...ect Balance the supply and exhaust air flows by adjusting values for Fan1 and Fan2 in the operating parameters setting menu of control panel with touchscreen display refer to section 1 5 of Operating...

Страница 18: ...fort functions despite similarity to any standard connectors External similarity of connectors does not guarantee compatibility connected devices may fail or damage the Unit Failure of the Unit due to...

Страница 19: ...equipped with suitable power circuit breaker Power supply 230V 50Hz 5A Maximum electric power consumption fans 252W Maximum electric power consumption preheater 3000W Maximum electric power consumptio...

Страница 20: ...e based on readings of auxiliary CO2 or humidity sensors connected Away reduction of ventilation power while away from home by security system or external switch Function can be activated by short cir...

Страница 21: ...ing S2 switch does not block the usage of function refer to section 9 3 6 Additional system settings IT IS PROHIBITED to connect the functions connector directly to electrical wiring network Optional...

Страница 22: ...ntrol board electrical wiring diagram Figure 10 Control board electrical wiring diagram IMPORTANT Make sure that the Unit is disconnected from mains supply before connecting or disconnecting system co...

Страница 23: ...ity sensor AI1 DI2 function Away GND AI0 DI3 function CO2 sensor 24V Not used DI1 DI1 function Boost GND DI0 DI0 function Fire alarm GND Tach1 Exhaust fan tacho signal GND Tach0 Supply fan tacho signa...

Страница 24: ...t is powered Failure of the Unit or WiFi controller caused by improper connection will void the warranty 9 1 1 Downloading the app Download the OXYGEN WiFi app for your smartphone or tablet from the A...

Страница 25: ...r 2 minutes If You fail to connect while it is active broadcasting will stop Slightly press and release immediately the hidden button through the small hole on WiFi controller body with thin screwdriv...

Страница 26: ...using browser Safari Chrome or similar by entering 192 168 4 1 in the address field Make sure that your device smartphone or tablet is connected to OXYGEN_xxxxxx WiFi network you may be asked to conf...

Страница 27: ...een of control app 9 1 4 Setting up weekly operation program Up to 4 different ventilation modes can be set for each day of week Set the desired operation program for the selected day or days of the w...

Страница 28: ...Ventilation boost activation After the selected time previously set or scheduled ventilation intensity will be activated 9 1 6 Away Activate selected decreased ventilation intensity until the selected...

Страница 29: ...clicking RESET button order replacement filter set by clicking troley icon Figure 18 Filter menu 9 1 8 Resetting WiFi controller to factory defaults If it is necessary to reset WiFi controller to fact...

Страница 30: ...touchscreen display 9 2 1 Standby mode Touchscreen display of control panel will only display the time of day in standby mode if the Unit is switched off If the Unit is in operation settings of desire...

Страница 31: ...valve state depends on device configuration Preheater state This menu enables to Activate the boost mode by single touch of button Access the settings menu Set the desired room air temperature Set the...

Страница 32: ...cold season air supplied to the room can be additionally heated by a separately purchased duct heater installed in the ventilation system IMPORTANT Availability of feature depends on device configurat...

Страница 33: ...ode settings menu Weekly operation program will be saved by clicking back arrow button IMPORTANT Click on the round button next to schedule button in main menu to activate a weekly operation program G...

Страница 34: ...rer of the Unit or its local representative You may control the Unit by app installed on smartphone or tablet by purchasing the WiFi controller 9 3 Control panel with a knob Control panel with a knob...

Страница 35: ...r filters IMPORTANT Higher than usually power consumption is to be expected when the Unit is operating in this mode 9 3 3 Failure indicator The flashing red led indicates that failure of the Unit comp...

Страница 36: ...ter the Unit reset procedure has been performed contact manufacturer of the Unit or its local representative 9 3 5 Resetting the filter lifetime meter Filter lifetime meter has to be reset after air f...

Страница 37: ...setting P2 boost mode power setting P3 supply fan power adjustment P4 exhaust fan power adjustment S1 reset button S2 switches for disabling OFF or activating ON boost 1 and away 2 functions Figure 2...

Страница 38: ...ng air filters Shut down the Unit by control panel make sure that fans have completely stopped Open the lid of the filter that you intend to change marked by OXYGEN by firmly gripping it and pulling o...

Страница 39: ...rs can result in ventilation power decrease and higher than usually power consumption IMPORTANT Only original manufacturer recommended filters should be used The use of low quality third party filters...

Страница 40: ...is connected to mains supply Power circuit breaker is ON If RESET button is being displayed on touchscreen control panel refer to section 9 2 5 Failure indication or flashing red led of control panel...

Страница 41: ...as JSC Company code 304288834 VAT code LT100010366918 Bank account LT42 7044 0600 0810 3886 SWIFT CBVILT2X AB SEB bank Address Birzelio 23 osios g 23G 50220 Kaunas Lithuania Phone No 370 627 26666 oxy...

Отзывы: