Options
Figure 25.
NAVconfig Options page
The Options page includes some optional settings that can be configured to tailor the RT1003
to specific applications. Figure 25 shows the available options. To adjust the settings, click
the default value in the Setting column to activate the cell. A description on each option and
how to adjust it is found below.
IMU output rate
The standard output rate of the RT1003 is 100 Hz, however this can be increased to 250 Hz
with the application of a special IMU high-rate feature code. On devices where the feature
code has been applied, the IMU output rate option allows the output rate to be set to 100, 200
or 250 Hz. On devices where the IMU high-rate feature code has not been applied, this option
is ignored, regardless of its setting.
Vehicle starts
If the vehicle being measured will be level during initialisation (to within about 5°) select
Level. This reduces the initialisation time by about 40 seconds as an initial roll and pitch