background image

 

Praktika T-05(K) speedgate 

 16 

reset when power is turned off. In order to return to the initial modification 

it is needed to re-do the above sequence. 

8.5. Control with card collector 

 

The  card  collector  is  set  in  the  standby  mode  after  power-up.  It  is 

necessary to present access card to switch the mode. 

 

Passage with permanent cards  

When an authorized permanent visitor card is presented to the reader 

card  collector  unlocks  the  speedgate  for  the  time  specified  by  ACS 

controller  (depending  on  the  operating  mode;  for  5  seconds  in  pulse 

mode).  During  the  specified  time  interval  other  cards  are  not  accepted. 

When  the  passage  is  performed  or  the  specified  time  interval  is  expired 

card  collector  switches  into  standby  mode  and  can  collect  the  next  card. 

Green arrow turns on on the LED panel, indicating the authorization of the 

passage. 

 

Passage with guest cards  

Guest  card  shall  be  inserted  into  the  card  hole  up  to  the  stop 

otherwise  it  will  be  ignored.  In  case  the  presented  card  is  authorized,  the 

card collector collects it and then unlocks OD for 5 seconds. 

 

 

Содержание Praktika T-05

Страница 1: ...Operational manual www oxgard com info oxgard com Tel 7 812 366 15 94 Praktika T 05 K speedgate ...

Страница 2: ......

Страница 3: ...d collector 11 7 1 Card collector purpose 11 7 2 Product design 12 7 3 Removing guest cards from card collector 13 8 Speedgate operation 13 8 1 Turn on 13 8 2 Operating modes 13 8 3 Control with remote control panel 13 8 4 Adjustment of remote control panel 15 8 5 Control with card collector 16 Appendix 1 Troubleshooting for speedgate 18 Appendix 2 Troubleshooting for card collector 18 ...

Страница 4: ... 05 K speedgate 4 List of abbreviations PS power supply FA fire alarm RC remote control ACS access control system OD operating device Speedgate firmware version FW v1 4 2 2 Card collector firmware version FWv1 52 ...

Страница 5: ...way stations etc To ensure easy and quick passage of people it is recommended to install one speedgate for every 500 people working in one shift 2 Delivery set Table 1 Delivery set Item Qty pcs Praktika T 05 К speedgate 1 Remote control panel with cable 1 Hatch lock key 8 Datasheet 1 Installation guidelines 1 Operational manual 1 SORMAT PFG LB12 50 anchor 12 М12х60 DIN912 GOST 11738 84 hexagon scr...

Страница 6: ...depending on passage lane mm 660 900 1050х1500х500 1050х1500х620 107х107х25 Weight of side unit depending on passage lane kg 660 900 110 0 113 0 0 5 Temperature range 0 C operation transportation and storage 1 40 1 40 1 40 1 40 Atmosphere relative humidity no more than 80 80 Throughput people per minute 30 Card collector capacity pcs More than 500 Max number of connected RC panels pcs 2 Lifetime y...

Страница 7: ...5 values mentioned at a nominal supply voltage optional to form a passage area required 2 side units i e 2 power supply 12V 5A The manufacturer reserves the right to change the packaging specifications and appearance without notice 4 Product design Speedgate housing Speedgate housing is made of brushed stainless steel wings are made of tempered glass The design of the speedgate can be equipped wit...

Страница 8: ...ate LED panel Display panel of the speedgate is made of artificial stone with an insertion made of acrylic glass Speedgate operating modes are displayed on the panel in the form of mnemonic signs depicting authorization and non authorization of passage Fig 2 ...

Страница 9: ...play Remote Control Panel The housing of RC panel is made of polished stainless steel On the front side there are control buttons and LED indicators of RC operational modes Fig 3 The standard supplied cable is 5 m long Fig 3 General view of remote control ...

Страница 10: ...r closed transport containers is permitted for short periods no more than 3 days Before startup the speedgate must be kept in a room with normal climate conditions for 12 hours after storage in unheated rooms Dimensions of container 1280х 800х 1650 mm HxWxL 6 Safety requirements CAUTION Failure to comply with the safety requirements specified in this section may result in damage to human life and ...

Страница 11: ... damage to human life and health total or partial loss of workability of products and or auxiliary equipment for non compliance of the safety requirements specified in this section as well as terminate the product warranty IT IS NOT ALLOWED TO Set the power supply inside the speedgate housing as this might lead to electric shock to persons Set the speedgate other than in dry and heated places Impe...

Страница 12: ...ose Card collector Fig 4 is designed for collection and storage of proximity access cards at the exit from the facility Flexible logic of the controller allows the integration of the card reader with any access control systems 7 2 Product design Fig 4 General view of the card collector ...

Страница 13: ...ver of the card collector This solution provides maximum flexibility for installation and connecting of the card collector 7 3 Removing guest cards from card collector 7 3 1 Open the hatch lock of card collector with a key Fig 4 7 3 2 Put a bag to collect cards not supplied underneath storage device 7 3 3 Lift the storage shutter to remove cards 7 3 4 Lower the storage shutter and close the hatch ...

Страница 14: ...tton is equipped with the LED indicator displaying operation of the speedgate The Stop mode Stop mode is set when the speedgate is turned on Wings are closed Switch from another mode to Stop is performed by pressing button 2 in this case LED indicator above button 2 turns red In this mode the passage is non authorized in both directions The single passage mode Button 1 3 turns on single passage mo...

Страница 15: ... by pressing button 4 while in any other mode In this mode the speedgate will open wings towards exit direction Green indicator on the RC panel will turn on button 4 8 4 Adjustment of remote control panel Speedgate can be set in various ways in relation to the user In some cases it is needed to reverse left right passage buttons This can be done by the following operations Power off the speedgate ...

Страница 16: ... speedgate for the time specified by ACS controller depending on the operating mode for 5 seconds in pulse mode During the specified time interval other cards are not accepted When the passage is performed or the specified time interval is expired card collector switches into standby mode and can collect the next card Green arrow turns on on the LED panel indicating the authorization of the passag...

Страница 17: ...d collector in the standard operating mode remove cards from the storage device see Article 7 3 Emergency mode During the operation of the card collector there might be a situation when a card or a foreign object becomes jammed by shutter of the card collector To resolve such situations is an emergency mode Open the hatch of the card collector using the key Fig 4 Press and hold BUT1 button on the ...

Страница 18: ...able 7 Troubleshooting for speedgate Fault Remedy PS unit is connected but the speedgate does not work Check the connection cable Check the fuses on motherboard RC panel does not work Check the RC panel connection If 12 and GND contacts are connected properly try to interchange positions of CL and CH ...

Страница 19: ...Operational manual 19 Appendix 2 Troubleshooting for card collector LED r b L7113 F3C Optotransistor y b L7113 Fig 6 Location of optocouplers of card collector ...

Страница 20: ...w sensor optocoupler is broken Fig 6 Check the condition of the cables and connectors If D9 LED on the board of the card collector does not turn red the fault is caused by the malfunction of motherboard If D9 LED on the board of the card collector turns red set the jumper on Full_ph connector if LED D9 then goes off the alarm stops the Red Cross does not blink the fault is caused by defective opto...

Страница 21: ...n BUT1 1 IR LED1 Vtyp 1 2 B If V 5 V LED or cable defective 2 Card1_ph Vtyp 0 1 B Vmax 2 5 V If V 2 5 In all right If V 2 5 V disaligment or LED and phototransistor fault If V 5 V the phototransistor or cable are defective Card collector collects a guest card and provides an audio signal for 1 second Defective lower optocoupler Fig 6 Check the voltage at the connectors without removing the connect...

Страница 22: ...Praktika T 05 K speedgate 22 ...

Страница 23: ...Operational manual 23 ...

Страница 24: ...OOO Vozrozdenie 192289 Saint Petersburg Sofiyskaya st 66 Tel fax 7 812 366 15 94 www oxgard com info oxgard com ...

Отзывы: