Installation guidelines
27
Appendix 1. Summary of data bus CAN2.0
Remote control panel uses a modern jam-resistant bus of standard
CAN2.0. According to the standard CAN2.0 a length of signal cable can
reach the values more than one kilometer, however correct operation at
such distances depends on many factors. At the distances more than 25
meters – it must be used twisted pair Cat5e or Cat6. Total electrical
resistance for power wire of the remote control panel for direct current
shall not exceed 50 Ohm. If this requirement is unable to comply with one
can install additional PS for 12V/100m
А (minimal operating supply
voltage of remote control panel – 7.5V). At that for correct operation 3
wires coming from turnstile CL, CH, GND are sufficient. Two control
panels may be connected to one turnstile.
An important feature of CAN 2.0 bus is the availability of 120 Ohm
resistor at the bus ends. Such resistor has already been installed in
the standard remote control panel.
Содержание Cube C-02
Страница 1: ...Installation guidelines www oxgard com info oxgard com Tel 7 812 366 15 94 Cube 02 turnstile...
Страница 2: ......
Страница 26: ...Cube 02 turnstile 26 Fig 15 Connecting diagram of control panel to ACS controller...
Страница 29: ...Installation guidelines 29 Appendix 3 Diagram of the turnstile and its connection...
Страница 30: ...Cube 02 turnstile 30...
Страница 31: ...Installation guidelines 31...